CV-M532
10. Specifications
Scanning system | EIA 525 lines |
| 30 frames/sec. |
CCD sensor | Monochrome "1/3" Hyper HAD IT CCD |
Sensing area | 4.9 mm (h) x 3.7 mm (v) |
Effective pixels | 768 (h) x 494 (v) |
Elements in video output | 758 (h) x 486 (v) |
Cell size | 6.35 (h) x 7.4 (v) µm |
Resolution (horizontal) | 570 TV lines |
Resolution (vertical) | 485 TV lines |
Sensitivity on sensor | 0.2 lx |
S/N ratio | >56 dB (AGC off, Gamma 1) |
Video output | Composite VS signal 1.0 Vpp, 75 Ohm |
Gamma | 0.45 or 1.0 |
Gain | Manual – Automatic. 0 to +15 dB by potentiometer or AGC |
Scanning | 2:1 interlace – |
Accumulation | Field – frame |
Synchronization | Int. |
HD sync. input/output | 4V, 75 Ohm* |
VD sync. input/output | 4V, 75 Ohm* |
Trigger input | 4V, 75 Ohm* |
Trigger input duration | >64 µsec to <1 msec. |
WEN output (write enable) | 4V, 75 Ohm |
EEN output (exposure enable) | 4V, 75 Ohm |
Pixel clock output (optional) | 4V, 75 Ohm sine |
Normal shutter | Off, 1/100, 1/250, 1/500, 1/1000, 1/2000, 1/4500, 1/10,000 sec. |
Edge | 1/60, 1/125, 1/250, 1/500, 1/1000, 1/2000, 1/4500, 1/10,000 sec. |
Pulse width controlled shutter | >1 H (64 µsec.) to <60 msec. |
Start/stop trigger shutter | 1/77 sec to 1/10,000 sec. |
Long time exposure | 1 field to ∞. Duration between ext. VD pulses |
Operating temperature | |
Humidity | 20 – 80% |
Storage temp./humidity | |
Power | 12V DC ±10%. 3.7W |
Lens mount | M10.5 x 0.5 |
Dimensions (camera Head) | ø12x 50 mm |
Mass | 230 g |
*HD sync., VD sync./(Trigger) input or output by internal jumpers. Factory setting: HD/VD input. Inputs TTL or 75 Ohm terminated by internal jumpers. Factory setting: 75 Ohm terminated.
Note: Above specifications are subject to change without notice.
10.1. Spectral Sensitivity
| 1.0 |
|
|
|
|
|
|
response | 0.8 |
|
|
|
|
|
|
0.6 |
|
|
|
|
|
| |
|
|
|
|
|
|
| |
Relative | 0.4 |
|
|
|
|
|
|
0.2 |
|
|
|
|
|
| |
|
|
|
|
|
|
| |
| 0.0 |
|
|
|
|
|
|
| 400 | 500 | 600 | 700 | 800 | 900 | 1000 |
Wave length (nm)
- 21 -