SCS150SI/SCS160SI/SCS180.6S

150W Powered Sub/ Plate Amp

LINE VOLTAGE

Yes/No

Hi/Lo Line

Unit

Notes

 

US 120vac/60Hz

Yes

108-132

Vrms

Normal Operation

 

Asia 100vac/50Hz

Yes

90-110

Vrms

Normal Operation

 

 

 

 

 

 

 

Parameter

Specification

Unit

QA Test Limits

Conditions

Notes

Amp Section

 

 

 

 

 

Type (Class AB, D, other)

D

D

n/a

 

 

Load Impedance (speaker)

4

Ohms

n/a

Nominal

 

Rated Output Power

150

Watts

145

1 input driven

 

THD@ Rated Power

0.08

%

1

22k filter

 

THD @ 1 Watt

0.1

%

0.5

22k filter

 

DC Offset

10

mV-DC

20

@ Speaker Outputs

 

 

 

 

 

 

Measured at speaker terminals, Output

Damping factor

>100

DF

30

 

power 140 Watts THD 0.1 %

 

 

 

 

 

 

Input Sensitivity

 

 

 

 

 

Input Frequency

50

Hz

50

Nominal Freq.

1 input driven

Line Input (L&R)

250

mVrms

±2dB

To Rated Power

1 input driven

LFE Input

145

mVrms

±2dB

To Rated Power

LFE input driven only

Speaker/Hi Level Input

2

Vrms

±2dB

To Rated Power

(-20 dB below Line In)...1 input driven

 

 

 

 

 

 

Signal to Noise

 

 

 

 

 

SNR-A-Weighted

100

dBA

85

rel. to rated power

A-Weighting filter

SNR-unweighted

90

dBr

80

rel. to rated power

22k filter

SNR @ 1W-unweighted

60

dBr

55

rel. to 1W Output

22k filter

 

 

 

 

Volume @max, using RMS reading

 

Residual Noise Floor

1

mVrms

2

DMM/VOM (or A/P)

 

 

 

 

 

Volume @max, w/ A/P Swept Bandpass

 

Residual Noise Floor

1

mVrms(max)

2

Measurement (Line freq.+ harmonics)

 

 

 

 

 

 

 

Input Impedance

 

 

 

 

 

Line input L&R , LFE

>15

K ohms

n/a

Nominal

 

Speaker/Hi Level Input

4.7

K ohms

n/a

Nominal

 

 

 

 

 

 

 

Filters

 

 

 

 

 

Left & Right Low Pass fixed

Hz

--

±2dB

 

 

Slope & Q

4th

dB/Octave

n/a

 

 

LFE Low Pass fixed

Hz

--

±2dB

 

 

Slope & Q

2nd

dB/Octave

n/a

 

 

Subsonic filter (HPF)

Hz

--

±2dB

 

 

Slope & Q

2nd

dB/Octave

n/a

 

 

 

 

 

 

 

 

Limiter

YES

--

n/a

 

 

 

 

 

 

 

 

Features

 

 

 

 

 

LFE Input

YES

 

functional

 

BW Limited to 500 Hz

Volume pot Taper (lin/log)

log

--

functional

 

 

ATO

YES

 

functional

 

 

 

 

 

 

 

 

Signal Sensing (ATO)

 

 

 

 

 

ATO test Frequency

50

Hz

functional

2mV@50Hz into Line Input w/ 1 ch.

 

ATO Line Level

2

mV

functional

 

driven

 

ATO Speaker level input

50

mV

fucntional

50mV@50Hz into Line Input w/ 1 ch.

 

driven

 

 

 

 

 

Amp connected and AC on, then input

 

ATO Turn-on time

5

ms

functional

signal applied

 

Auto Mute/ Turn-OFF Time

15

minutes

functional

T before muting, after signal is removed

Auto turn of time (T) must be 10 > T <15

 

 

 

 

 

 

Power on Delay time

3

sec.

functional

AC Power Applied

 

 

 

 

 

 

 

Transients/Pops

 

 

 

 

 

ATO Transient

5

mV-peak

10

@ Speaker Outputs

 

Turn-on Transient

50

mV-peak

100

@ Speaker Outputs

AC Line cycled from OFF to ON

Turn-off Transient

50

mV-peak

100

@ Speaker Outputs

AC Line cycled from ON to OFF

 

 

 

 

 

 

Efficiency

 

 

 

 

 

 

 

 

 

 

Maximum allowable input power under

 

 

 

 

 

nominal Input voltage and frequency, HOT

Stand-by Input Power

14

Watts

16

@ nom. line voltage

or COLD operation.

Power Cons.@rated power

230

Watts

250

@ nom. line voltage

140 Watts @ 4 Ohms nominal line voltage

 

 

 

 

 

 

Protection

 

 

 

 

 

Short Circuit Protection

YES

--

functional

Direct short at output

 

 

 

 

 

 

Temperature rise should not exceed 35K

Thermal Protection

65 deg. C

--

functional

@1/8 max unclipped Power

rise

DC Offset Protection

YES

--

functional

DC present at Speaker Out leads

Relay or crowbar (for driver/fire protection)

Line Fuse Rating

 

 

 

 

 

US Version

3.15

Amps

 

Type-T or Slo Blo

External fuse with UL/SEMKO rated holder

2

Page 3
Image 3
JBL SCS160SI, SCS180.6S, SCS150SI service manual 150W Powered Sub/ Plate Amp