SCS150SI/SCS160SI/SCS180.6S

Test Set Up and Procedure

Equipment needed:

Function/signal generator/sweep generator

Integrated Amplifier

Multimeter

Speaker cables

General Unit Function (UUT = Unit Under Test)

1)From the signal generator, connect one line level (RCA) cable to the Subwoofer Line Level Input jacks L/R on the UUT. Use a Y-cable from a mono source if necessary to connect to both inputs. Do not connect to the single LFE input.

2)Turn on generator; adjust to 100mV, 50 Hz.

3)Plug in UUT; turn the power switch ON. LED should switch from Red to Green. Turn LEVEL control full clockwise (MAX)

4)LED should Green; immediate and vigorous bass response should be heard and felt from port tube opening.

5)Turn off generator, turn LEVEL control full counterclockwise (MIN), and disconnect RCA cable.

6)Connect one pair of speaker cables to Speaker Level input terminal (IN) on UUT. Cables should be connected to an integrated amplifier fed by the signal generator.

7)Turn on generator and adjust so that speaker level input at the amplifier is 2.0V, 50 Hz. Turn LEVEL control full clockwise.

8)Green LED should light; immediate and vigorous bass response should be heard and felt from the port tube opening.

Sweep Function

1)Follow steps 6-8 above, using a sweep generator as a signal source.

2)Sweep generator from 20Hz to 300Hz. Listen to the cabinet and drivers for any rattles, clicks, buzzes or any other noises. If any unusual noises are heard, remove woofers and test.

Driver Function

1)Remove woofer from cabinet (instructions on exploded view drawing); detach + and - wire clips.

2)Check DC resistance of woofer; it should be 3.4 ohms ±10%

3)Connect a pair of speaker cables to driver terminals. Cables should be connected to an integrated amplifier fed by a signal generator. Turn on generator and adjust so that speaker level output is 5.0V.

4)Sweep generator from 20Hz to 1kHz. Listen to driver for any rubbing, buzzing, or other unusual noises.

9

Page 10
Image 10
JBL SCS180.6S, SCS160SI, SCS150SI service manual Test Set Up and Procedure