Venue SUB12
VENUE SUB12 | 150W Powered Sub/ Plate Amp |
| |||
|
|
|
|
|
|
LINE VOLTAGE | Yes/No | Hi/Lo Line | Nom. | Unit | Notes |
US 120vac/60Hz | Yes | 120 | Vrms | Normal Operation | |
EU | Yes | 230 | Vrms | Normal operation, MOMS required | |
|
|
|
|
|
|
|
|
| QA Test |
|
|
Parameter | Specification | Unit | Limits | Conditions | Notes |
Amp Section |
|
|
|
|
|
Type (Class AB, D, other) | D | n/a | n/a |
|
|
Rated Output Power (120VAC) | 150 | Watts | 140 |
| Domestic version only 120 |
Rated Output Power (230VAC) | 150 | Watts | 130 |
| EU Version only 230 |
|
|
|
|
| Average RMS power, 3/20 Cycles 50 Hz, Driven |
AVG RMS Dynamic Power | 250 | Watts | 225 |
| 6dB above its input sensitivity sensitivity |
THD @ Rated Power | 0.3 | % | 1 | 22k filter | 145 Watts |
THD @ 1 Watt | 0.1 | % | 0.5 | 22k filter |
|
DC Offset | 10 | 30 | @ Speaker Outputs |
| |
|
|
|
|
| Measured at the speaker cable. 150 Watts @ |
Damping factor | >50 | DF | 35 | Measured at amplifier board | THD < 0.1 % @ 50 Hz |
|
|
|
|
|
|
Input Sensitivity |
|
|
|
|
|
Input Frequency | 50 | Hz | 50 | Nominal Freq. |
|
L&R | 240 | mVrms | ±2dB | To 150 Watts | Single input driven |
LFE input | 240 | mVrms | ±2dB | To 150 Watts | Single input driven, LFE switch ON |
Speaker/Hi Level Input | 2.4 | Vrms | ±2dB | To 150 Watts | Single input driven |
|
|
|
|
|
|
Signal to Noise |
|
|
|
|
|
90 | dBA | 70 | relative to rated power | ||
85 | dBr | 70 | relative to rated power | 22k filter | |
SNR rel. | 65 | dBr | 60 | relative to 1W Output | 22k filter |
|
|
|
| Volume @max, using RMS reading | Line level inputs must be terminated using |
Residual Noise Floor | 1 | mVrms | 2 | DMM/VOM (or A/P) BW=20 Khz. | 1KOHM |
|
|
|
| Volume @max, w/ A/P Swept |
|
|
|
| 2 | Bandpass Measurement (Line | Line level inputs must be terminated using |
Residual Noise Floor | 1.5 | mVrms(max) | freq.+ harmonics) (BW=20 Khz) | 1KOHM | |
|
|
|
|
|
|
Input Impedance |
|
|
|
|
|
Line Input (L, R,LFE) | 10K | ohms | n/a | Nominal |
|
Speaker/Hi Level Input | > 4.7K | ohms | n/a | Nominal |
|
|
|
|
|
|
|
Filters |
|
|
|
|
|
|
|
|
|
| See AP curves 2nd order variable + 2nd order |
LP filter 4th order fixed | Hz | ± 10 |
| ||
Subsonic filter (HPF) 3rd Order | Fixed |
|
|
|
|
LFE Low pass 2nd order | 200>LP<1K | Hz |
| LFE input driven only |
|
|
|
|
| Speaker input driven - Speaker out |
|
HP speaker out connector | 200 | Hz | ± 10 | loaded with 4 Ohms | (Applies only to 230V Model) |
Note: 120V Models do not |
|
|
| Speaker input driven - Speaker out |
|
have speaker output | 100 | Hz | ± 10 | loaded with 8 Ohms | (Applies only to 230V Model) |
|
|
|
|
|
|
Limiter |
|
|
|
|
|
THD at Max. Output Power | n/a | n/a | functional | Maximum Output Power | Maximum THD as a result of limiting. |
|
|
|
|
|
|
Features |
|
|
|
| |
Volume pot Taper (lin/log) | LOG | functional |
| A Taper | |
HP Speaker out | 230v version |
| functional |
| Refer to Filter section |
Phase switch | deg | functional |
|
| |
LP Filter defeat switch | YES |
| functional |
| Disables LP filter, intended for LFE |
|
|
|
|
|
|
Input Configuration |
|
|
|
|
|
Line In (L,R) & LFE | YES | functional |
| Dual RCA jack | |
Spkr/Hi Level In | YES | functional |
| Binding post connector L&R | |
|
|
|
|
|
|
Signal Sensing (ATO) |
|
|
|
|
|
YES |
| functional |
|
| |
ATO Input test frequency | 50 | Hz | functional |
|
|
ATO Level LFE Input | 4 | mV | functional |
| Maximum acceptable level. |
ATO Level Speaker in | 50 | mV | functional |
| Maximum acceptable level. |
|
|
|
| Amp connected and AC on, then |
|
ATO | 5 | ms | functional | input signal applied |
|
|
|
|
| T before muting, after signal is | Auto turn of time (T) must be 5 > T < 15 |
Auto Mute/ | 15 | minutes | 15 | removed | Minutes |
|
|
|
|
|
|
Power on Delay time | 3 | sec. | 4 | AC Power Applied |
|
|
|
|
|
|
|
3