DPC-2 AC Power Ratings

Description

115VAC

 

230VAC

 

 

 

 

 

 

Idle

 

30W

 

 

 

 

 

 

Quescient Power Draw

 

30W

 

 

 

 

 

 

1/8th Power, Pink Noise (UL/CSA)

85W, 1.5A rms

 

85W, 1A rms

 

1/3rd Power, Pink Noise

2 A

 

1 A

 

 

 

 

 

 

Maximum Power Draw

 

1440W

 

 

 

 

Inrush Current

Inrush current limiting via PTC soft-start

 

 

 

 

AC Power Panel Connectors (UL/CSA)

12A Max, 100-10VAC/220-240VAC, 50-60 Hz.

16 AWG

 

Class 1 Wiring

 

 

(1.5 mm2)

 

 

 

 

 

Inlet Connector Rating (UL/CSA)

5A

 

3A

 

 

 

 

 

 

Outlet Connector Rating (UL/CSA)

7A

 

9A

 

 

 

 

 

 

Line Voltage Selection: DrivePack® DPC-2 amplifier models feature a user-configurable dual-voltage international power supply and is easily set to the appropriate local AC Power Mains voltage supply. A 2- way slide switch is provided to select 100-120VAC or 200-240VAC operation, 50/60Hz.

Your DPC-2 amplifier module is factory set to 230 VAC operation to avoid damage from overvoltage conditions at any location worldwide. Applying 230 VAC to the DPC-2 with the unit set to 115V can cause serious damage. Before you set up your VP-DPC-2 series speaker for the first time, verify that the line voltage selector setting is appropriate for the AC Mains supply voltage in your area.

Changing the AC Mains Supply Voltage Setting

Make sure that the speaker is powered off and the AC power cable is disconnected from the speaker.

Locate the voltage selector switch directly above the blue PowerCon connector on the main control panel.

Slide the voltage selector switch to 115V for (100-120V~) or 230V for (220-240V~) range setting as required for your area.

After having reconfirmed that the correct voltage is selected, reconnect the blue AC Line Input PowerCon connector and power the unit up.

DO NOT UNDER ANY CIRCUMSTANCES OPERATE THE UNIT WITH THE WRONG VOLTAGE SELECTED. DOING SO MAY RESULT IN SERIOUS DAMAGE TO YOUR SPEAKER SYSTEM WHICH WILL NOT BE COVERED BY WARRANTY.

Line Voltage Tolerance: The amp will operate normally (with expected de-rating in power output during low line conditions) over a range of 100-120VAC +/-10% or 200-240VAC +/-10% AC input voltage. The amp will shut down for voltages below nominal line and self protect for over-voltage beyond 15% nominal line.

CAUTION: Continuous voltages 10% beyond high line at either 120VAC or 240VAC operation ranges can disrupt performance of the JBL DRIVEPACK! To avoid activation of amplifier low line/ high line protection which will interrupt audio performance, the system operator should maintain

AC supply voltages within the rated voltage windows.

JBL Professional 17

Page 17
Image 17
JBL Professional manual DPC-2 AC Power Ratings, Changing the AC Mains Supply Voltage Setting