RM3 SERIES BACKREFLECTION METER

USER’S MANUAL

6.Terminate the measurement jumper just before the output connector, and hold the termination point steady (figure 5a for single-mode(except 980nm), and figure 5b for single- mode(980nm) and multimode).

NOTE

The termination technique is different depending on the type of the RM Meter used : single-mode (except 980 nm), single-mode (980nm) or multimode.

Please refer to the Termination Techniques section above.

7.Press the Store BR0 key. The key lamp lights to indicate that the background backreflection has been stored. The BR0 value is used in the calculation of the DUT backreflection at the selected wavelength.

8.Remove the termination.

Measuring Backreflection

To measure backreflection and power from a unit after setting up the meter (see the Setting Up the Meter for Backreflection Measurements section):

1.Clean the output connector of the measurement jumper and the input connector of the DUT, and mate the two.

2.Press the λ key to select the wavelength at which the measurement is to be made.

3.Terminate the measurement jumper immediately after the DUT, and hold the termination point steady. The meter displays the backreflection between the two termination points that is caused by the fiber, all connections, and the DUT. This area is shown within the dashed line in Figure 6a for single-mode (except 980nm), and in Figure 6b for single-mode (980nm) and multimode.

4.If necessary, terminate the fiber for BR0 again just before the DUT to eliminate the backreflection caused by the fiber and all connections before the DUT.

5.Press the Store BR0 key. The key lamp lights to indicate that the function is on.

6.If the backreflection setup has been done previously (BR 0 light is on), press the BR0 button to delete the currently stored BR0 value. The BR0 light turns off.

7.Press λ and repeat step 6 to delete the stored BR0 value for another wavelength.

8.Release the termination. The meter now displays the backreflection of the DUT only.

9.If a measurement is to be made at a second wavelength, repeat steps 1 through 8.

The small amount of reflections that BR0 represents can be polarization sensitive, and multiple reflections can cause interference effects that can make the reflections very sensitive to

10112341 Rev 002

Page 26 of 39

Page 26
Image 26
JDS Uniphase RM3750 user manual Measuring Backreflection

RM3750 specifications

The JDS Uniphase RM3750 is a cutting-edge optical spectrum analyzer that has garnered attention in various telecommunications and photonics applications. Renowned for its versatility and accuracy, the RM3750 combines advanced technologies to provide users with unprecedented measurement capabilities, making it an essential tool for researchers and engineers working in fiber optics, laser development, and spectral analysis.

One of the standout features of the RM3750 is its wide dynamic range. This feature allows users to obtain precise measurements across a broad spectrum of optical signals, which is crucial in environments where signal strength can vary significantly. The analyzer is designed to handle both high-intensity signals and weak optical events, ensuring that no detail is missed during analysis.

The RM3750 incorporates a high-resolution detection mechanism that enables it to distinguish closely spaced wavelengths. This characteristic is particularly beneficial in applications where wavelength spacing is minimal, such as in dense wavelength division multiplexing (DWDM) systems. The high resolution also allows for accurate characterization of spectral features, including signal peaks and noise.

In addition to its impressive measurement capabilities, the RM3750 supports advanced analysis and real-time monitoring. Users can visualize spectral data through an intuitive graphical interface, which aids in the quick interpretation of results. The instrument is equipped with real-time data processing capabilities, allowing users to observe changes in optical signals as they occur, a critical feature for dynamic environments like live signal monitoring.

The JDS Uniphase RM3750 is not only about hardware; it also comes with an array of software tools designed to enhance functionality and ease of use. These tools allow for automated measurements, data logging, and integration with other laboratory instruments. Moreover, the ability to export data in various formats facilitates easy sharing and analysis across platforms.

Another notable characteristic of the RM3750 is its compact design and robust build quality. This ensures that it can operate effectively in demanding laboratory conditions while being portable enough for field applications.

In conclusion, the JDS Uniphase RM3750 optical spectrum analyzer stands out for its combinations of wide dynamic range, high resolution, real-time monitoring, and user-friendly software integration. These characteristics make it an exceptional tool for professionals in telecommunications and optical research, enabling them to conduct more accurate and insightful measurements.