Jenn-Air CCG2423, JGC7430 Installatioofapplian Nce, Connectinappliancetogassupplyg, Iimportant

Models: CCG2423 CCG2523 JGC7536 JGC7430

1 10
Download 10 pages 58.32 Kb
Page 3
Image 3
INSTALLATIOOFAPPLIAN NCE

INSTALLATIOOFAPPLIAN NCE

Theinstallationf thisappliancemustconformwithlocalcodesr,inthe absenceof local codas,with the NationalFuel Gas Code,ANSI Z223.1-LatestEdition,r,inCanada,CAN/CGA-B149InstallationCode,latestEdition.

This appliance,when installed,must be electricallygroundedin accordancewithlocalcodesor,intheabsenceof localcodes,withthe NationalElectricalCodeANSI/NFPANo.70-latestEdition,or,inCanada, currentCSAStandardC22.1CanadianElectricalCode,Part1.

Allsupplypiping,exceptas noted,shouldusecommonNationalPipe Thread(N.P.T.)For.all pipeconnectionsusean approvedpipejoint compoundrasistantotheactionofLP gas.

CAUTIONWarr:antyisvoidonJenn-Airequipmentinstalledotherthanas

recommendedbyThisapplianceismanufacturerdesignedor usew. iththe appliancegaspressure

regulatorsuppliedwiththisapplianceItmu.stbeinstalledinthegasway

aheadofthegasmanifoldentranceItispresetforusewithn.aturalgasand

mustbe convertedas, describedonpage6, forusewithLPgas.(See figures10and11.)

Thisapplianceisdesignedtooperateat a pressureof 5 inchesofwater columnon naturalgasor,if convertedforusewithLPgas(propaneor butane),10incheswatercolumnMakesurethis.applianceissuppliedwith andadjustedforthetypeofgasforwhichit isdesigned.

Thisappliancewasadjustedatthefactoryorusewithnaturalgas.If,atany time,thisapplianceistobe usedwitha differenttypeof gas,all ofthe conversionadjustmentsdescribedonpages5 and7 mustbemadebya qualifiedservicetechnicianbeforeattemptingtooperatethecooktopon thatgas.Naturalgasshouldbesuppliedtotheappliancepressureregulator ata linepressurbetween6 and14inchesofwatercolumnor,ifconverted forIF'gas,between11and14 inches,

WARNING:If the linepressuresupplyingthe appliancepressure regulatorexceeds14" W.C.(anygas),an externalregulatormustbeI installedinthegaslineaheadoftheapplianceregulatortoreducetheI pressureto nomorethan14" W.C. Failureto do thiscanresultin

malfunctionanddamagetotheapplance.

Insurethisapplianceisadjustedforthetypeofgassuppliedtoitandthat thegassupplypressuretotheapplianceregulatoriswithintheproper

pressureange.

If thisisa 36"widemodel,orif it isa 30" widemodelandnoother applianceis to be installedin the cabinetrybelowit, proceedas

instructeundepraragraphI.

ElectricIf thisisWall30Ovenis"widemodelandato be installJednnin cabin-AlModelW3rtrybelow,proc0XXXorWeedas131instructedunderparagrapIIh.

Donotremoveprotectivecapfrompipestubatmanifoldentranceuntil

NOTE:In Canada,gasutilizationcodasprohibituseofstreetelbowsUse.

standardpipeelbowsandmakemodificationsto theseinstructionsas necessaryeadytojoing. assupplypipingtoappliance.

CONNECTINAPPLIANCETOGASSUPPLYG

ATRAINEDSERVICEMANORGASAPPLIANCEINSTALLERMUST MAKETHEGASSUPPLYCONNECTION.Leaktastingoltheappliance shall be conductedby the installeraccordingto the instructions given.

1.IF NOOTHERAPPLIANCEIS TO BEINSTALLEDBELOWTHIS

COOKTOP

Jointheappliancepressureegulatorsuppliedwiththisappliancetothe entrancethreadsoftheGasManifoldTheapplianceregulatoris.marked

witha directionarrowindial catingcorrecdirectionf gasflowEnsur.the

applianceregulatoisr installedwiththearrowpointingtowardthegas manifoldentranceTightentheappli.anceregulator20 to30 ft-lbsof torque.

IIMPORTANT

INpievertightentopejointcompoundmoreasthan35istanttotheactionofLPf -lbsoftorqueAl. wgasysuseanapproved.

Installtheapplianceinitscountercutout.

Makethegasconnectiontotheinletof theappliancpressureregulator with1/2"malepipethreads.

Installa manualshut-offvalvein anaccessiblelocationn thegasline aheadoftheappliancepressureregulatorndexternaltothisappliaocfore thepurposefturningonorshuttingoffgastotheappliance.

Makeadditionpipeal connectionsasnecessaryaheadoftheshut-offvalve tothegassupplysourceAssu.reallpipejointconnectionsaregastight.

IMPORTANT

Applya non-corrosiveleakdetectionfluidtoalljointsandfittingsinthe gasconnectionbetweenthesupplylineshut-offvalveandtherange. Includegasfittingsandjointsintherangeifconnectionsweredisturbed duringinstallationCheckforl.eaksBubblesappearingoundfittings! andconnectionswillindicatea leakI.f a leakappearstu, rnoffsupplyline

gasshut-offvalve,tightenconnections,turnonthesupplylinegasshut offvalve,andretestforleaks.Nevertestforgas leakswithan open flame.

ILLUSTRATIVE GAS SUPPLY PIPING (NO OTHER APPLIANCE BELOWCOOKTOP)

_

(REAROFAPPLIANCE)

I

BURNERBOX

I

I

I I _ MANIFOLD

I_, _ ENTRANCE

_APPLIANCE

__REGULATORPRESSURE

/I

_ ALLPIPEJOINTS

MANUAL

SHUTOFF

VALVE

.j..

_ 1/2 N.P.T.

i

--TOGAS

ELBOWINLET FIGURE3

3

Page 3
Image 3
Jenn-Air CCG2423, JGC7430, JGC7536, CCG2523 Installatioofapplian Nce, Connectinappliancetogassupplyg, Iimportant