30" (76.2 cm) and 36" (91.4 cm) Sealed Gas Cooktop
PRODUCT MODEL NUMBERS
JGC8430CD JGC8536BD
PRODUCT DIMENSIONS – 30" MODEL (JGC8430CD)
E
F
Gas supply: The installation of this appliance must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI
All supply piping, except as noted, should use common National Pipe Thread (N.P.T.). For all pipe connections use an approved pipe joint compound resistant to the action of LP gas.
This appliance is designed for use with the appliance gas pressure regulator supplied with this appliance. It must be installed in the gas line ahead of the gas manifold entrance. It is preset for use with natural gas and must be converted, as described in the Installation Instructions for use with LP gas.
This appliance is designed to operate at a pressure of 5" of water column on natural gas or, if converted for use with LP gas (propane or butane), 10" water column. Make sure this appliance is supplied with and adjusted for the type of gas for which it is designed.
This appliance was adjusted at the factory for use with natural gas. If, at any time, this appliance is to be used with a different type of gas, all of the conversion adjustments described in the Installation Instructions must
J
MANIFOLD
ENTRANCE
D |
|
|
I | H |
|
|
| |
|
| |
| Dimensions | |
"A" | (73.0 cm) | |
"B" | (52.4 cm) | |
"C" | 2" min. | (5.1 cm) |
"D" | (12.9 cm) | |
"E" | 30" | (76.2 cm) |
"F" | (55.2 cm) | |
"G" | (9.4 cm) | |
"H" | (31.6 cm) | |
"I" | (4.4 cm) | |
"J" | (4.4 cm) | |
|
|
|
AB
C
G
IMPORTANT: Cutout dimensions are critical. Dimensions must be measured and cut accurately to within ±1/16" (0.2 cm) to ensure proper fit.
be made by a qualified service technician before attempting to operate the cooktop on that gas. Natural gas should be supplied to the
PRODUCT DIMENSIONS – 36" MODEL (JGC8536BD)
appliance pressure regulator at a line pressure between 6" and 14" of water column or, if converted for LP gas, between 11" and 14".
Make the gas connection to the inlet of the appliance pressure regulator with 1/2" NPT male pipe threads.
Install a manual
Make additional pipe connections as necessary ahead of the
Electrical: See page 2.
J
MANIFOLD
ENTRANCE
D
IH
Dimensions
"A" | (88.6 cm) | |
"B" | (52.9 cm) | |
"C" | 2" min. | (5.1 cm) |
"D" | (11.6 cm) | |
"E" | 36" | (91.4 cm) |
"F" | (54.8 cm) | |
"G" | (9.6 cm) | |
"H" | (39.4 cm) | |
"I" | (4.4 cm) | |
"J" | (4.4 cm) | |
|
|
|
E
F
G AB
C
IMPORTANT: Cutout dimensions are critical. Dimensions must be measured and cut accurately to within ±1/16" (0.2 cm) to ensure proper fit.
Page 1 of 2
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation | Ref. |
Instructions packed with product. Specifications subject to change without notice. |