Option 3 - Évacuation entre

Option 4 - Évacuation

les solives au plancher

derrière le garde-pieds du

 

placard

6" (15,2 cm)

0 pi

 

(0,0 m)

A

B

3¹⁄₄" x 10"

A (8,3 x 25,4 cm) B

Raccord de 3¹⁄₄" x 10"

4,5 pi

(8,3 cm x 25,4 cm) vers

(1,4 m)

6" (15,2 cm)

 

 

 

Raccord de 6" (15,2 cm) vers

1 pi

3¹⁄₄" x 10"

(0,3 m)

(8,3 cm x 25,4 cm)

 

A. Bouche de décharge murale

A. Bouche de décharge murale

B. Conduit de dia. 6" (15,2 cm)

B. Conduit de dia. 6" (15,2 cm)

pour sortie à travers le mur

pour sortie à travers le mur

Installations sur dalle de béton - Évacuation par le mur

Raccord coudé à 90° de 3¹⁄₄" x

5,0 pi

10" (8,3 cm x 25,4 cm)

(1,5 m)

vers 6" (15,2 cm)

 

B

AD

NC

M

L

 

K

 

 

 

E

F G

H

I

J

Raccord coudé à 90° de 6"

5,0 pi

(15,2 cm) vers 3¹⁄₄" x 10"

(1,5 m)

(8,3 cm x 25,4 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Coude à 90° de

 

 

 

 

 

 

3¹⁄₄" x 10" (8,3 cm x 25,4 cm)

5,0 pi

 

(1,5 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

Coude plat de

 

 

 

 

 

 

3¹⁄₄" x 10" (8,3 cm x 25,4 cm)

12 pi

 

(3,7 m)

 

 

 

 

 

 

 

A. Bouche de décharge murale

B. Conduit métallique de dia. 6" (15,2 cm) C. 16" (40,6 cm) maximum

D. Conduit PVC dia. 6" (15,2 cm) (pour égout) E. Conduit métallique de dia. 6" (15,2 cm)

F. Raccord PVC de dia. 6" (15,2 cm) G. Dalle de béton

H. Conduit PVC pour égout de dia. 6" (15,2 cm)

I. Coude à 90° en PVC pour égout de dia. 6" (15,2 cm) J. Gravier ou sable compacté tout autour du tuyau.

K. 30 pi (9,1 m) max.

L. Coude à 90° en PVC pour égout de dia. 6" (15,2 cm) M. Raccord PVC de dia. 6" (15,2 cm)

N. 12" (30,5 cm) minimum

Calcul de la longueur du circuit d’évacuation

Pour calculer la longueur effective du circuit d’évacuation nécessaire, additionner les longueurs équivalentes (en pieds ou mètres) de tous les composants utilisés dans le système.

Composant

Conduit de diamètre de 6"

 

(15,2 cm)

Coude à 45°

2,5 pi

 

(0,8 m)

 

 

Coude à 90°

5,0 pi

 

(1,5 m)

Bouche de décharge murale de

0 pi

3¹⁄₄" x 10" (8,3 cm x 25,4 cm)

(0,0 m)

Exemple de circuit d’évacuation

bouche de décharge murale

coude à 90˚

6 pi (1,8 m)

2pi

(0,6 m)

1 coude à 90°

= 5 pi (1,5 m)

Section droite de 8 pi (2,4 m)

= 8 pi (2,4 m)

1 bouche de décharge murale

= 0 pi (0 m)

 

 

Longueur totale

= 13 pi (3,9 m)

REMARQUE : On déconseille l’emploi d’un conduit flexible. Un conduit flexible peut causer une contre-pression et des turbulences d’air, qui réduisent considérablement la performance.

19

Page 19
Image 19
Jenn-Air W10526003A Installations sur dalle de béton Évacuation par le mur, Calcul de la longueur du circuit d’évacuation

W10526003A specifications

The Jenn-Air W10526003A is a premium appliance component designed to enhance the performance and functionality of modern kitchens. This high-quality product is primarily a replacement part for various Jenn-Air refrigerator models, ensuring that your appliance remains efficient and reliable over time. Understanding the main features, technologies, and characteristics of the W10526003A can help homeowners and appliance repair technicians make informed decisions when it comes to appliance maintenance.

One of the standout features of the W10526003A is its durable construction. Made from high-quality materials, this component is designed to withstand the rigors of daily use while maintaining its functionality. This resilience is essential for homeowners who rely on their refrigerators to keep food fresh and safe to consume.

The W10526003A is engineered with advanced technology to ensure optimal performance. It is designed to fit specific Jenn-Air models seamlessly, contributing to the overall efficiency of the appliance. The precise engineering behind this part reduces the likelihood of malfunctions, providing peace of mind for users who depend on their refrigerator for food preservation.

Another significant characteristic of the Jenn-Air W10526003A is its ease of installation. This component can be swapped out with minimal effort, making it accessible for DIY enthusiasts and professional repair technicians alike. Clear instructions are typically provided, ensuring that users can complete the installation process without hassle.

In addition to its durable and efficient design, the W10526003A is also built with energy efficiency in mind. By ensuring that the refrigerator operates at optimal levels, this replacement part can contribute to lower energy consumption, which is not only beneficial for the environment but also decreases utility bills.

Moreover, the W10526003A is compatible with a range of Jenn-Air refrigerator models, making it a versatile choice for various configurations. This compatibility allows users to confidently select this part, knowing that it will work effectively with their specific appliances.

In conclusion, the Jenn-Air W10526003A represents a high-quality replacement option for those looking to maintain or repair their refrigerators. With its durable construction, advanced technology, easy installation process, and energy efficiency, it stands out as a reliable choice for enhancing the overall performance of Jenn-Air appliances. By investing in this component, homeowners can ensure that their kitchen remains a well-functioning hub for food storage and preparation.