TROUBLE- SHOOTING

!WARNING

Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.

OBSERVED FAULT

Heater burns, but creates puffs of smoke.

Heater will not burn steady.

Heater burns with odor.

Heater smokes continuously.

POSSIBLE CAUSE

A)Water in fuel

B)Wrong fuel

Wrong pump pressure

Dirty air output, air intake, and lint filters

Dirty fuel filter

Dirt in nozzle

REMEDY

A)Check fuel tank for bubbles of water in bottom. If found, remove fuel and clean tank (see Storage, page 8).

B)Remove wrong fuel and clean tank (see Storage, page 8). Fill with correct fuel.

See Pump Pressure Adjustment, page 13.

See Air Output, Air Intake and Lint Filters, page 13.

See Fuel Filter, page 11.

See Nozzle, pages 14 and 15.

Heater will not

Heater almost out of fuel

Add fuel to tank. See

ignite, but motor

 

Fuels, page 6.

runs.

Wrong pump pressure

See Pump Pressure

 

 

 

Adjustment, page 13.

 

Carbon deposits on spark

See Spark Plug, page 12.

 

plug and/or improper gap

 

 

Dirty fuel filter

See Fuel Filter, page 11.

 

Dirt in nozzle

See Nozzle, pages 14 and 15.

 

Water in fuel tank

Drain and flush fuel tank

 

 

with clean kerosene. See

 

 

Storage, page 8.

 

! WARNING: High voltage!

 

Electronic ignitor not

Make sure electronic

 

grounded (earthed)

ignitor mounting is tight.

 

Bad electronic ignitor

Replace electronic

 

 

ignitor.

 

 

 

Motor does not start

Binding pump rotor

If fan is hard to turn, see

when heater is

 

Pump Rotor, page 16.

plugged in, fan

Solid state relay not

Wait two minutes before

rotates slowly or

allowed to reset

trying to restart heater.

 

does not turn.

9

Page 9
Image 9
Jet Tools J150ECA, J100ECA owner manual TROUBLE- Shooting, Observed Fault