230 Volt Operation
If 230V, single phase operation is desired, the fol lowing instructions must be followed:
1. Disconnect the machine from the power source.
2. This bandsaw is supplied with four motor leads that are connected f or 115V operation, as shown in
Figure A. Reconnect these four motor leads f or 230V operation, as shown in Figure B.
3. The 115V attachment plug supplied with the bandsaw must be replaced wit h a UL/CSA listed plug
suitable for 230V operation. Contact your local Authorized JET Serv ice Center or qualified
electrician for proper procedures to instal l the plug. The bandsaw must comply with all local and
national codes after the 230V pl ug is installed.
4. The bandsaw with a 230V plug should only be connected to an outlet havi ng the same configuration.
No adapter is available or should be used with the 230V plug.
Important: In all cases (115 or 230 volts), make cert ain the receptacle in question is prop erly
grounded. If you arenot sure, have a registered electrician checkthe receptacle.