ID Conflict

When two devices share the same SCSI ID, a conflict occurs. This conflict must
be corrected before the SCSI bus will work properly. If a conflict occurs, check
all jumper settings to ensure that no devices on the bus share the same ID. Also
check all other devices on the bus outside of the enclosure.
Front Status LEDs
A status indicator is located on each canister. A 'Blue' light indicates normal drive
activity. A 'Red' light indicates a device fault. If all canisters display a 'Red' light
that is blinking on and off it indicates that there is a system fault. A system fault
is either a power supply or blower failure. The power supply and blowers are not
field replaceable units. A fault with either the power supply or blowers will
require replacement of the entire unit. Refer to Chapter 5.
External I/O Connection
The external I/O connections are located on the back of the unit. The figure below
shows the external I/O connections available.
SSttoorrBBllaaddeeTM SCSI JBOD Installation Guide Rev A 4-3
StorBladeTM
SCSI A
IN SCSI B
IN
SCSI A
OUT SCSI B
OUT
AC Inlet
Power
Supply
Fan
Drive Status
Indicators
A blue light on a single canister
indicates device activity or busy.
A red light on a single canister indicates
a device fault.
Alarm
Reset
Button Power Fan FLT Temp FLT