Before carrying out any maintenance or cleaning isolate the cooker hood from the mains supply.
Charcoal Filters
In the recirculation mode the charcoal filters absorb smells and unwanted odours.
The charcoal filters cannot be cleaned, we recommend they should be replaced approximately every three months or more often if the hood is used for more than three hours per day.
To Remove/Replace the Char- coal Filters
•First remove the Grease Filters.
•Remove the saturated activated charcoal filter by releasing the fixing hooks as illustrated.
•Position the new charcoal filter in the position marked and while holding the filter replace the fixing hooks as illustrated
This appliance can be a possible fire hazard if the grease and charcoal filters are not cleaned and replaced as recommended.
Changing the Halogen Lamp
•Unscrew the two screws to release the metal sur- round.
•Remove the lamp from the holder by pulling the lamp downwards.
•Replace the lamp with a new one of the same type, mak- ing sure that you insert the two pins properly into the housings on the lamp holder.
•Replace the Support, fixing it in place with the two screws removed as above.
Replacement filters and light bulbs can be ob- tained from your local Service Force Centre.
12