Johnson Controls 340968-XIM-A-0108 General, Approvals, Inspection, Renewal Parts

Models: 340968-XIM-A-0108

1 24
Download 24 pages 36.53 Kb
Page 3
Image 3
GENERAL

340968-XIM-A-0108

GENERAL

YORK Model DNA units are cooling/heating air conditioners designed for outdoor installation. Only gas piping, electric power and duct connections are required at the point of installation.

The gas-fired heaters have spark to pilot ignition. The tubular heat exchangers are aluminized steel.

APPROVALS

Design certified by CGA and AGA listed as follows:

1.For use as a forced air furnace with cooling unit.

2.For outdoor installation only.

3.For installation directly on combustible flooring or, in U.S., on wood flooring or Class A; B; C roof covering material.

This appliance is not to be used for temporary heating of buildings or structures under construction.

Installer should pay particular attention to the words; NOTE, CAUTION, and WARNING. NOTES are intended to clarify or make the installation easier. CAUTIONS are given to prevent equipment damage. WARNINGS are given to alert the installer that personal injury and/or equipment damage may result if installation procedure is not handled properly.

INSPECTION

As soon as a unit is received, it should be inspected for possi- ble damage during transit. If damage is evident, the extent of the damage should be noted on the carrier's freight bill. A separate request for inspection by the carrier's agent should be made in writing.

RENEWAL PARTS

Contact your local York® parts distribution center for autho- rized replacement parts.

4.For installation on combustible material.

5.For use with natural gas and/or propane (LP) gas. Not suitable for use with conventional venting systems.

This product must be installed in strict compliance with the enclosed installation instructions and any applicable local, state, and national codes includ- ing, but not limited to, building, electrical and mechanical codes.

Improper installation may create a condition where the operation of the product could cause personal injury or property damage.

 

 

 

 

 

 

 

D

 

2

 

N

A

 

0

3

6

 

N

 

0

3

6

 

0

6

 

 

 

 

 

PRODUCT CATEGORY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOLTAGE CODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

06 = 208/230-1-60

 

D = Single Package Air Conditioner

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRODUCT GENERATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 = 2nd Generation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 = 3rd Generation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOMINAL GAS HEATING

 

 

PRODUCT IDENTIFIER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT CAPACITY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NA = 10 SEER Gas Heat/Electric

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036 = 36,000 BTUH

 

 

 

NOMINAL COOLING

 

 

 

 

 

FACTORY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

056 = 56,000 BTUH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAPACITY (MBH)

 

 

INSTALLED GAS HEAT

 

 

 

065 = 65,000 BTUH

 

 

 

 

 

018 = 18,000 BTUH

 

N = Natural Gas Heat Installed

 

 

 

072 = 72,000 BTUH

 

 

 

 

 

 

 

 

 

090 = 90,000 BTUH

 

 

 

 

 

024 = 24,000 BTUH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

110 = 110,000 BTUH

 

 

 

 

 

030 = 30,000 BTUH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036 = 36,000 BTUH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

042 = 42,000 BTUH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

060 = 60,000 BUTH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIGURE 1 - PRODUCT NOMENCLATURE

Johnson Controls Unitary Products

3

Page 3
Image 3
Johnson Controls 340968-XIM-A-0108 installation manual General, Approvals, Inspection, Renewal Parts, Product Nomenclature