DEMO MODE USER’S MANUAL
Premium High Definition Touch Screen Communicating Control Models:
POWER-UP SEQUENCE
The communicating control will load the following screens upon initial power up:
Screen 1 – Set date and time by selecting a field and using the up/down arrows provided. See figure at right.
Screen 2 – The control will display the Software Revision.
Screen 3 – The control “listens” for network traffic for a random interval between 1 – 10 seconds. Screen 4 – The control “gathers” system information.
Screen 5 – Set the Mode of Operation to Demo Mode. See figure at right. Screen 6 – Select the type of indoor equipment to demo.
Screen 7 – Select the type of outdoor equipment to demo.
NON-ADJUSTABLE SETTINGS/FUNCTIONALITY
Homeowner:
Setting / Functionality
View Equipment / Accessory Details
Access Path
Menu > Status
Notes
Device icons are not selectable.
Service:
Setting / Functionality | Access Path |
View Equipment / Accessory Details | Main Status screen |
Edit Dealer Information / Logo | Menu > Tools/Settings > Dealer Information |
Notes
Device icons are not selectable. Edit button is not present.
System Event:
The communicating control will display the following system event 2 minutes after power‐up: Air Filter Reminder Expired – applies to all systems
Equipment Faults:
The communicating control will display the following equipment faults 3 and 4 minutes after power‐up: Limit Switch Open – applies to all Air Handler applications
Soft Limit Warning – applies to all Furnace applications Ambient Sensor Open – applies to all Heat Pump applications HPS Lockout – applies to all Air Conditioner applications
Status Screen:
With each Refresh button press, the system will toggle through pre‐programmed states for all devices:
9 States – applies to Heat Pump application |
|
| |||
|
| UV | EAC |
|
|
Thermostat | Humidifier | (HP4) | (HP15) | AH | AC |
ON | OFF | ON | OFF | FAULT | OFF |
|
|
|
|
| TIME |
ON | OFF | ON | ON | FAN | DELAY |
ON | OFF | 10% | 10% | FAN | LO COOL |
ON | OFF | 10% | 10% | FAN | HI COOL |
ON | ON | ON | ON | FAN | LO HEAT |
ON | ON | ON | ON | FAN | HI HEAT |
ON | OFF | 10% | 10% | 4.8KW | DEFROST |
ON | 10% | 10% | 10% | 14.4KW | HI HEAT |
ON | 10% | ON | ON | 14.4KW | FAULT |
6 States – applies to Air Conditioner applications
| Humidifier |
|
|
|
|
Thermostat | (AC8) | UV | EAC | AH | AC |
ON | OFF | ON | OFF | FAULT | OFF |
|
|
|
|
| TIME |
ON | OFF | ON | ON | FAN | DELAY |
|
|
|
|
| LO |
ON | OFF | 10% | 10% | FAN | COOL |
|
|
|
|
| HI |
ON | OFF | ON | 10% | FAN | COOL |
ON | 10% | ON | ON | 4.8KW | OFF |
ON | ON | ON | ON | 14.4KW | FAULT |
AVAILABLE SETTINGS
Reference the User’s Information and Installation Manuals for adjusting the all other settings not listed above.
Subject to change without notice. Published in U.S.A.
Copyright © 2010 by Johnson Controls, Inc. All rights reserved.
Johnson Controls Unitary Products
5005 York Drive