Jotul Wood Stove manual Corner installation with wall shield, Combustible wall

Models: Wood Stove

1 28
Download 28 pages 57.3 Kb
Page 24
Image 24
Combustible wall

Fig. 17 Parallel installation in a corner with wall shield

Combustible wall

Wall shield

Must be 1” off the wall and 1” off the floor.

With single wall pipe, the shield must be 49” high measured off the floor.

With double wall pipe, the shield must be 37” high measured off the floor.

Both shields MUST extend and join in the corner.

The wall shield must extend a minimum of 4” (102 mm) past the side of the stove

The wall shield must extend a minimum of 7” (178mm) past the ash lip of the stove

Fig. 18 Corner installation with wall shield

Wall shield

Must be 1” off the wall and 1” off the floor.

With single wall pipe, the shield must be 49”.

With the double wall pipe, the shield must be 37” high.

Both shields MUST extend and join in the corner.

Combustible wall

The wall shield must extend a minimum of 7” (178mm) past the front corner of the stove.

The wall shield must extend a minimum of 7” (178mm) past the front corner of the stove.

Fig. 19

A

B

A:Lift to open

B:Left - closed, Right - open

(Measurements in cm - for Canada)