![](/images/new-backgrounds/1110493/11049325x1.webp)
Replace an FPC in an M40 Router
4.Take the FPC offline by pressing and holding its offline button for 5 seconds or until the green OK LED next to the button goes out. The offline button for each FPC is located on the craft interface just below the FPC slot.
5.Disconnect the cables from the PICs on the FPC. If a PIC uses
Do not look directly into the ends of
Do not leave a transceiver uncovered. The safety cap keeps the port clean and prevents accidental exposure to laser light.
Avoid bending
6.Unscrew the thumbscrews at the top and bottom of the FPC.
7.Pull the ends of the extractor clips, which are adjacent to the thumbscrews, away from the face of the FPC. See Figure 9.
8.Grasp the FPC with both hands and slide it about halfway out of the chassis.
9.Place one hand underneath the FPC to support it, and slide it completely out of the chassis. Set the FPC on the antistatic foam mat prepared in Step 1,
To avoid damaging any components, use extra care when laying the FPC
Do not stack the FPC on top of or under any other component.
10.If you are removing or replacing PICs on the FPC, see the instructions in the M40 Internet Router Hardware Guide.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
FPC Installation Instructions | 13 |
|