31
Item
“IRIS MODE”
“MANUAL
LEVEL”
“GAIN”
“LEVEL”
“EXPOSURE” ScreenFunction/Variable Values
Switch according to the lens in use.
“AUTO” :When using auto iris lens
“MANUAL” :When using manual iris lens
For setting the iris level when “IRIS MODE” is set to “MANUAL”.
Increase value :Opens the iris.
Decrease value :Closes iris.
{Variable Values : 0 - 128 - 255}
Note
“When “IRIS MODE” is set to “AUTO”, “MANUAL LEVEL” item selection will be
disabled. (Displayed as “- - - - - -”)
For switching the electric sensitivity mode.
“STEP” :Gain boost level can be altered using the “LEVEL” item.
“V.GAIN” :Gain boost level can be fine-tuned using the “LEVEL” item.
“ALC” :Alters gain boost level automatically according to the
brightness.
Set the maximum value at the “ALC LIMIT” item. ☞ Page 33
Gain boost level can be altered when gain boost mode is set as “STEP” or “V.GAIN”.
{Variable “STEP” Values: –3, 0, +3, +6, +9, +12, +15, +18dB, LOLUX}
{Variable “V.GAIN” Values: –3 - 0 - 18dB 0.2dB Step}
Note
“When “GAIN” is set to “ALC”, “LEVEL” item selection will be disabled.
(Displayed as “- - - - - -”)
Settings in bold are factory settings