Connection/Installation

Connection (Continued)

Memo v Do not connect DC 12 V and AC 24 V cables at the same time.

vWhen using a DC 12 V power supply, ensure that the polarities of the cable are correct.

mAC 220 V - AC 240 V (TK-C9201EG/TK-C9301EG)

When using this camera, install it near the socket so that power disconnection may be made immediately.

Connecting the Monitor

Connect with a 75 K coaxial cable (BNC) such as RG-59.

Connecting the Alarm Input/Output Terminal (TK-C9300U/TK- C9300E/TK-C9301EG only)

Menu settings may be required depending on the connected equipment. (Refer to [AUX FUNCTION] in the separate "MENU SETTING".)

The default setting has been set to alarm input (IN:ALARM).

mAlarm input terminal

Connect the infrared sensor, door sensor, metal sensor, manual switch sensor and the like.

vTo prevent noise from entering the internal circuit, supply non-voltage setting signal to the alarm input signal.

vDo not supply voltage.

vUsing the menu, you can select whether to set to alarm when the contact is short (MAKE), or when the contact is open (BREAK).

vSupply such that the alarm signal stays at a minimum of 200 ms or more. Otherwise, the alarm signal may not be recognized.

 

OFF

SEE INSTRUCTION

D/N AUTO

MANUAL

BLC OFF

ON

 

LCD

CRT

VIDEO

WIDE-D OFF

ON

OUT

MONITOR TYPE

 

 

 

 

FOCUS

 

 

ADJUST

CLASS 2 ONLY (U TYPE)

ISOLATED POWER

SET

AUX(IN)

Please use a shielded cable.

GND

mAlarm output terminal

Connect to alarm devices such as alarm, indicator, light or buzzer.

vThe alarm output signal is open collector output and turns ON during an alarm. (Maximum voltage 16 V, current 30 mA)

vThis terminal has a polarity. Make sure to connect such that a higher voltage is output from the + terminal than from the - terminal. Otherwise, it will result in damages.

100AUX(OUT)

GND

8