65
10-2 Rear Panel’s Inputs/Outputs
Terminals Signal levels Remarks
About 2
seconds
Min. 400 msec.
Min. 400 msec.
Alarm
Record mode
LV: 0 V
Max. 10 mA
LV: 0 V
HV: 5 V ~ 12 V
HV: 12 V
HV: 5 V
HV:12 V
(output impedance: 4.7 kohms)
Record mode:
repeat recording ON/auto rewind ON
Tape end Manual
operation
Warning Warning reset
HV: 12 V
(output impedance: 4.7 kohms)
Record mode:
repeat recording OFF/auto rewind OFF
ALARM IN
Alarm signal input
CAM SW OUT
Camera switching
signal output
ALARM REC OUT
Alarm recording
mode signal output
TAPE END OUT
Tape end signal
output
WARNING OUT
Warning signal
output
ALARM RST IN
Alarm signal reset
input
Input at ground
level
Open-collector
output
LV: 0 V
CLOCK RESET IN
Clock reset input Input at ground
level
About 100 msec.
About 100 msec.
LV: 0 V
CLOCK RESET
OUT
Clock reset output
Output at ground
level
2.5 - 3 sec. LV: 0 V
HV: 5 V
HV: 5 V
HV: 5 V
HV: 5 V
SERIES REC IN
Series recording
signal input
Input at ground
level
2.5 - 3 sec. LV: 0 V
SERIES REC OUT
Series recording
signal output
Output at ground
level
External recording
Min. 400 msec.
SERIES REC IN
External automatic
recording signal input
Input at ground
level
Input at high
level
Output at high
level
Output at high
level
Output at ground
level
During
recording
During
standby
1 field
Time
5m sec
GND
(Timelapse recording) The switching interval
can be set to “1 field”
or “1 frame” with the
<CAMERA SW> in the
<IN/OUT> setting
screen.
(With the menu switch
set to “1 field”)
Camera switching signal output
10 APPENDIXES