Control signal cables

These cables should be connected only when it is required to control the camera using the RS-442A or RS-485 signals. The use of 0.65 4-conductor twisted pair cables is recom- mended. With these cables, the maximum ex- tension distance is 1,200 m.

A

TX+

Connect to the other

B

TX-

side in pairs like this.

C

RX+

Connect to the other

D

RX-

side in pairs like this.

Genlock connection

With some systems, when the external sync signal is a composite video or black burst sig- nal genlocking by applying an external sync input requires the horizontal phase (H PHASE) and colour phase (SC COARSE) to be adjusted.

MEMO

Genlocking is not possible with a signal containing too much jitter, such as a VCR or videodisc playback signal.

For details, consult a JVC authorized dealer.

E-17

Page 17
Image 17
JVC TK-C1481 manual  Control signal cables,  Genlock connection