How to Use the External Control

7About the External Control

The Monitor has the MAKE/TRIGGER terminal, which allows you to control the monitor by the MAKE (make contact) or TRIG. (trigger) system selected in the function setting.

MAKE (make contact) system: Controls the function by short-circuiting the corresponding pin terminal to the GND pin terminal, or disconnecting (opening) it.

TRIG. (trigger) system: Controls the function by inputting the pulse signal instantaneously to the corresponding pin terminal.

*Select “MAKE” or “TRIG.” from “REMOTE SYSTEM” in SET-UP MENU. “REMOTE SYSTEM” on page 14

NOTES:

The external control has priority over operations using front panel buttons or menu functions of the monitor.

When using the make contact system, you cannot use the functions which are applied to the MAKE/TRIGGER terminal operating the front panel buttons or the menu of the monitor. (When using the trigger system you can also use those functions operating the monitor directly.)

7How to Use the MAKE/TRIGGER Terminal

7Function of the MAKE/TRIGGER terminal

The following are the configurations and the functions of the pin terminals of the RJ-45 connector. You can change the functions applied to the 1st to 6th pin terminals by setting “REMOTE SYSTEM” of SET-UP MENU.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO.

 

Functions to be controlled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

INP. A

Changes the input to INPUT A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

INP. C

Changes the input to INPUT C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

MARKER

Turns on/off MARKER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

ASPECT

Changes ASPECT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

TALLY

Controls the tally lamp

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

L. METER

Turns on/off AUDIO LEVEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Caution:

 

 

METER

 

 

 

7

 

External control

This is a female

 

 

 

 

8

 

GND

connecter.

 

 

 

 

7To change the functions applied to the pin terminals

1.Display SET-UP MENU, then move the MENU control to / to select “REMOTE SYSTEM,” then move it to .

2.Move the MENU control to / to select “CONTROL FORM,” then move it to / to select “SET.”

3.Move the MENU control to / to select the number of the pin terminal (PORT F1 – PORT F6)

you want to set, then move it to / to select the function.

NOTE:

• You cannot apply two or more functions to one terminal.