In order to prevent any fatal accidents caused by misoperation or mishandling the monitor, be fully aware of all the following precautions.
WARNINGS
To prevent fire or shock hazard, do not expose this monitor to rain or moisture. Dangerous high voltages are present inside the unit. Do not remove the back cover of the cabinet. When servicing the monitor, consult qualified service personnel. Never try to service it yourself.
WARNING : THIS APPARATUS MUST BE EARTHED.
Machine Noise Information Ordinance 3. GSGV, January 18, 1991: The sound pressure level at the operator position is equal or less than 70 dB(A) according to ISO 7779.
Improper operations, in particular alternation of high voltage or changing the type of tube may result in x-ray emission of considerable dose. A unit altered in such a way no longer meets the standards of certification, and must therefore no longer be operated.
This monitor is equipped with a 3-blade grounding-type
plug to satisfy FCC rule. If you are unable to insert the plug into the outlet, contact your electrician.
FCC INFORMATION (U.S.A. only)
CAUTION : Changes or modification not approved by JVC could void the user's authority to operate the equipment.
NOTE : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
–Reorient or relocate the receiving antenna.
–Increase the separation between the equipment and receiver.
–Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
–Consult the dealer or an experienced radio/TV technician for help.
Notice (U.S.A. only) | | |
This product utilizes both a Cathode Ray Tube (CRT) and | | |
other components that contain lead. Disposal of these | | |
materials may be regulated in your community due to | | |
environmental considerations. For disposal or recycling | | |
information please contact your local authorities, or the | | |
Electronics Industries Alliance: <http:// | www | .eiae.org.> |
Power cord
Power supply voltage | : AC 120 V | AC 230 V | AC 230 V |
Countries | : U.S.A. and Canada | European countries | United Kingdom |
Warning:
●Do not use the same Power Cord for AC 120 V as for AC 230 V. Doing so may cause malfunction, electric shock or fire.
Note for the United Kingdom power cord only
The plug on the United Kingdom power cord has a built-in fuse. When replacing the fuse, be sure to use only a correctly rated approved type, re-fit the fuse cover.
(Consult your dealer or qualified service personnel.)
How to replace the fuse
Open the fuse compartment with the blade screw driver, and
replace the fuse.
(* An example is shown in the illustration.)
Fuse
SCREEN BURN
●It is not recommended to keep a certain still image displayed on screen for a long time as well as displaying extremely bright images on screen. This may cause a burning (sticking) phenomenon on the screen of cathode-ray tube. This problem does
not occur as far as displaying normal video playback motion images.
Supplementary Explanation
= Information for monitor operation =
This monitor uses a high precision CRT (cathode ray tube). Please follow the procedures below.
*For stable operation of the CRT, approximately 30 minutes running time is required from the time the power is turned on.
*When the monitor is installed, it can be easily affected by surrounding magnetic fields, which can generate irregular color on the screen. When it is difficult to eradicate, degauss from outside using a degausser, etc.
PRECAUTIONS
●Use only the power source specified on the unit.
(120 V AC/230 V AC, 50 Hz/60Hz)
●When not using this unit for a long period of time, or when cleaning it, be sure to disconnect the power plug from the AC outlet.
●Do not allow anything to rest on the power cord. And do not place this unit where people will tread on the cord. Do not overload wall outlets or power cords as this can result in a fire or electric shock.
●Avoid using this unit under the following conditions:
–in extremely hot, cold or humid places,
–in dusty places,
–near appliances generating strong magnetic fields,
–in places subject to direct sunlight,
–in badly ventilated places,
–in automobiles with doors closed.
●Do not cover the ventilation slots while in operation as this could obstruct the required ventilation flow.
●When dust accumulates on the screen surface, clean it with a soft cloth.
●Unplug this unit from the AC outlet and refer servicing to qualified service personnel under the following conditions:
– when the power cord is frayed or the plug is damaged,
– if liquid has been spilled into the unit,
– if the unit has been dropped or the cabinet has been damaged,
– when the unit exhibits a distinct change in performance.
●Do not attempt to service this unit yourself as opening or removing covers may expose you to dangerous voltage or other hazards. Always refer servicing to qualified service personnel.
●When replacement parts are required, have the service personnel verify in writing that the replacement parts he/she uses have the same safety characteristics as the original parts. Use of manufacturer’s specified replacement parts
can prevent fire, shock, or other hazards.
●Upon completion of any servicing or repair work to this unit, please ask the service personnel to perform the safety check described in the manufacturer’s service literature.
●When this unit reaches the end of its useful life, improper disposal could result in a picture tube implosion. Ask qualified service personnel to dispose of this unit.
CONTENTS | |
SAFETY PRECAUTIONS | 2 |
CONTROLS AND FEATURES | 4 |
HOW TO HANDLE BASIC OPERATIONS | 7 |
HOW TO USE THE MENU FUNCTIONS | 8 |
HOW TO INITIALIZE THE SETTING | 11 |
BASIC CONNECTION EXAMPLE | 12 |
HOW TO USE EXTERNAL CONTROL | 14 |
TROUBLESHOOTING | 15 |
SPECIFICATIONS | 16 |