Click [Advanced Settings] and [Auto Patrol].

A B C D E

Memo:

Register the position in [PTZ Settings] of Built-in Viewer. (A Page 105)

Press the [OK] button to enable the new settings.

If the [OK] button is pressed upon entering an invalid value, a warning message will appear and the entry will be denied. Press the [Cancel] button to restore the invalid entry to the value before the change was made. If you press the [Cancel] button, other changed items will also be restored to the values before the change was made.

Note:

You can use the Digital PTZ for frame sizes 640 x 360 and 640 x 480 only. (A Page 17)

A No.

Switches camera images in sequence from No.0 to No.19.

 

 

B Title

Shows the title of position.

 

 

C Position

Sets a sequence of position numbers where the camera moves.

 

[Set values: 0 to 19]

 

 

D Stay Time

Sets a time interval to display the image of the respective position. (in seconds)

 

Select "Skip" for positions that you do not want to display by Auto Patrol.

[Set values: Skip, 10, 20, 30, 45, 60, 120] sec

E Moving Speed Set a movement speed to the target position.

[Set values: Moment, Low, Mid, High]

* The [Set values] in bold letters are factory defaults.