Power Connection
Note:
●Be sure to use an AC 24 V supply that is isolated from the primary power supply circuit. Using a variable voltage power supply will cause the camera and system to malfunction or breakdown.
●The unit is to be powered by an AC 24 V power supply. The AC 24 V power supply should conform to the following: Class 2 only (For USA), Isolated power supply only (For Europe and others).
Connecting the power cable
This connects the camera to AC24V power.
Power cable
To Power Supply
When using
Maximum |
| 40 m | 100 m | 170 m | 210 m |
connection |
|
|
|
|
|
distance |
|
|
|
|
|
|
|
|
|
|
|
Conductor |
| R1.0mm | R1.6mm | R2.0mm | R2.6mm |
Diameter |
| (18) and | (14) and | (12) and | (9) and |
(AWG No.) |
| above | above | above | above |
|
|
|
|
|
|
Warning
●The rated power of this product is AC 24 V, 50 Hz/60 Hz. Make sure to use it with the correct voltage.
●Supplying a power beyond the rated value may result in failures, smoke or fire. When the camera breaks down, turn off the power and contact our service center immediately.
●When a power beyond the rated value is supplied, the internal components may be damaged even if no abnormality is found on the appearance and operation of the camera. Please contact your nearest JVC dealer immediately for servicing (charged separately).
Memo:
●After DHCP timeout, all IP addresses of VN- V686U are set to 192.168.0.2 by default. When the power of multiple cameras within the same LAN environment are turned on at the same time, the IP address of the cameras overlap, thus preventing proper access. As such, make sure to turn on the power of the cameras one by one.
●In a system where multiple units of VN- V686U are used, turn on the power of only one unit to configure the IP address settings using the Internet Explorer. Upon doing so, turn on the power of the second unit and configure accordingly. Configure the camera settings using the same procedure.
●When overlapping of the IP address occurs, check to ensure that there is only one VN- V686U unit within the same LAN environment, and wait for a while (at least 10 minutes) or power off and on all network devices under the same LAN environment. Otherwise, access to
20