Section 28.23.29 Video Surveillance Remote Devices and Sensors

a.Lens mount

b.Back focus lock screw

c.Monitor Out setting switch

d.Camera reset button

e.4 pin Auto Iris connector

f.Power On lamp

5.Rear controls, connectors or indicators:

a.RCA connector: Monitor Video output – 1V peak to pe ak, 75 ohms resistance

b.3.5mm mini jack – monaural audio output

c.RJ-45 (Category 5): 10BASE-T/100BASE-TX Network connection (auto negotiation)

d.Alarm Terminal Block: Two (2) Alarm input, to (2) Alarm output

e.Power Terminal: AC power connection

H.Environmental

1.Temperature Range

a.14 to 122 degrees Fahrenheit (-10 to 50 degrees Celsius)

b.Recommended: 32 to 104 degrees Fahrenheit (0 to 40 degrees Celsius)

2.Relative Humidity Range

a.Operating: 20% to 80%, non-condensing.

3.The unit is suitable for indoor operation. Provide proper air ventilation and filtering to maintain operating temperature and air quality when mounted in equipment cabinets or other confined areas.

2.02MANUFACTURED UNITS

A.JVC Model VN-X35U : IP Camera

B.Included Accessories:

1.Installation Manual

2.API Guide

3.Active X Viewer

C.Optional Accessories:

1.JVC V. Networks Products

a.VN-N900U/1600U Digital video recorders

b.VN-RS800U – Video Management software

PART 3 EXECUTION

3.01INSTALLATION

A.Install the system in accordance with the equipment manufacturers recommended procedures.

B.Install system using generally acceptable industry practices for network appliances.

C.Ensure system and network configuration is fully coordinated with the Owner’s Information Technology Department

© Copyright 2009, Victor Company of Japan, Limited. All rights reserved. “JVC” is the trademark or registered trademark of Victor Company of Japan.

All non-metric weights and measures are approximate. Features and specifications are subject to change with out notice.

MasterFormat, SectionFormat and PageFormat are trademarks of the Construction Specification Institute.

8 of 9