FAULT INDICATIONS

English

BR VS 400 *USA

11

FAULT INDICATIONS

No or too little cleaning agent solution on the floor

Fill the tank with the cleaning agent solution

Check that the tank is firmly fitted

Unsatisfactory cleaning results

Replace worn rotary brooms

Check that the rotary broom or the pads match the application on hand.

Rotary brushes do not turn

Remove jammed foreign bodies

The appliance is overloaded, the overcurrent protection switch triggered, allow it to cool down. The appliance is operable again after approx. 30 s.

Use rotary brushes suitable for job

Mains circuit breaker triggers when the cleaner is switched on

Ensure adequate mains fuse protection (15 A time-lag) or use starting current limiter

Switch off other consumers or use other power circuit.

Cleaner runs unevenly or vibrates heavily

Check the proper fit of the rotary brooms

Exchange the right for the left hand rotary broom and vice versa

Soak the rotary brooms in hot water (approx. 15°C) for approx. 80 min.

If fault cannot be rectified, have unit checked by After-Sales Service.

TECHNICAL DATA

Mains fuse

 

 

(slow)

 

15 A

Power drive

 

 

Rated voltage

120 V (1~60Hz)

Nominal power consumption

 

Total

 

1,6 kW

Brush motor

 

1,55 kW

Spray pump

 

0,05 kW

Area performance

 

 

(theoretical)

 

450 m²/h

Brushes

 

 

Number

 

2 pieces

Diameter

 

95 mm

Tank

 

 

Capacity

 

3 Litres

option

 

10 Litres

Dimensions and weights

 

Length

 

530 mm

Width

 

450 mm

Height without protective

 

bracket

 

180 mm

Empty weight

 

30 kg

Working width

 

400 mm

Protection class

 

I

Noise emission

 

 

Mean sound level

 

 

according to IEC 60704-1

70 dB(A)

Machine vibration

 

 

according to ISO 5349

 

upper limbs

 

< 1m/s²