English | BR VS 400 *USA | 11 |
FAULT INDICATIONS
No or too little cleaning agent solution on the floor
–Fill the tank with the cleaning agent solution
–Check that the tank is firmly fitted
Unsatisfactory cleaning results
–Replace worn rotary brooms
–Check that the rotary broom or the pads match the application on hand.
Rotary brushes do not turn
–Remove jammed foreign bodies
–The appliance is overloaded, the overcurrent protection switch triggered, allow it to cool down. The appliance is operable again after approx. 30 s.
–Use rotary brushes suitable for job
Mains circuit breaker triggers when the cleaner is switched on
–Ensure adequate mains fuse protection (15 A
–Switch off other consumers or use other power circuit.
Cleaner runs unevenly or vibrates heavily
–Check the proper fit of the rotary brooms
–Exchange the right for the left hand rotary broom and vice versa
–Soak the rotary brooms in hot water (approx. 15°C) for approx. 80 min.
If fault cannot be rectified, have unit checked by
TECHNICAL DATA
Mains fuse |
|
|
(slow) |
| 15 A |
Power drive |
|
|
Rated voltage | 120 V (1~60Hz) | |
Nominal power consumption |
| |
Total |
| 1,6 kW |
Brush motor |
| 1,55 kW |
Spray pump |
| 0,05 kW |
Area performance |
|
|
(theoretical) |
| 450 m²/h |
Brushes |
|
|
Number |
| 2 pieces |
Diameter |
| 95 mm |
Tank |
|
|
Capacity |
| 3 Litres |
option |
| 10 Litres |
Dimensions and weights |
| |
Length |
| 530 mm |
Width |
| 450 mm |
Height without protective |
| |
bracket |
| 180 mm |
Empty weight |
| 30 kg |
Working width |
| 400 mm |
Protection class |
| I |
Noise emission |
|
|
Mean sound level |
|
|
according to IEC | 70 dB(A) | |
Machine vibration |
|
|
according to ISO 5349 |
| |
upper limbs |
| < 1m/s² |