WINTERIZING AND LONG-TERM STORAGE

WINTERIZING AND LONG-TERM STORAGE

Î1: Disconnect all water connections.

Î2: Turn on the machine for a few seconds, until the water which had remained in the pump exits, turn off immediately.

Î3: Do not allow high pressure hose to become kinked.

Î4: Store the machine and accesso- ries in a room which does not reach freezing temperatures. DO NOT store near furnace or other sources of heat as it may dry out the pump seals.

￿CAUTION

Failure to follow the above directions will result in damage to the pump as- sembly and accessories.

Kärcher also recommends the regular practice of using a pump protector like “Kärcher Pump Guard” to help during storage in the winter months.

MAINTENANCE INSTRUCTIONS

Kärcher pump

Initial Use

All Kärcher pumps ship with oil already inside direct from the factory. There is no need to add oil.

Pump Inspection

You should routinely make a visual in- spection of the pressure washer’s pump. If you notice oil leaking around the pump seals, you should take the pressure washer to a Kärcher-Autho- rized Service Center for repair. (You can locate a service center in your area online at www.karcher-usa.com/ser- vice.)

Pump Maintenance

The pump on your Kärcher pressure washer does not require maintenance. Any attempts to service or alter the pump may damage your pressure washer and void your product warranty.

Engine

Carry out maintenance tasks for the en- gine according to the specifications pro- vided in the operating instructions provided by engine manufacturer.