Technical data
Type |
| AV 06 | AV 09 | AV 11 | AV 12 |
|
|
|
|
|
|
Order no. |
| 211450 | 211453 | 211463 | 211473 |
|
|
|
|
|
|
Channels |
| ||||
|
|
|
|
|
|
Gain | dB | ||||
|
|
|
|
|
|
Elements |
| 4 | 6 | 9 | 11 |
|
|
|
|
|
|
Reception range | MHz | ||||
|
|
|
|
|
|
Horiz.°/vert.° | |||||
|
|
|
|
|
|
dB | |||||
|
|
|
|
|
|
Mast clamp range | mm Ø | ||||
|
|
|
|
|
|
Length | mm | 630 | 1,300 | 2,250 | 3,315 |
|
|
|
|
|
|
Wind load | N | 28 | 39 | 65 | 77 |
|
|
|
|
|
|
Packing unit/weight | pc./kg | 1/1.1 | 1/1.6 | 1/2.3 | 1/3.0 |
|
|
|
|
|
|
Packing unit dimensions | mm | 930 x 180 x 130 | 930 x 180 x 130 | 1,260 x 160 x 110 | 1,510 x 160 x 110 |
|
|
|
|
|
|
Suitable Kathrein telescopic masts
Type |
| ZSD 48 | ZSF 47 | ZSF 48 | ZSH 47 | ZSH 48 | ZSH 59 | ZSH 62 ²) | |
|
|
|
|
|
|
|
|
| |
Order no. |
| 218380 | 218385 | 218381 | 218386 | 218394 | 218382 | 218383 | |
|
|
|
|
|
|
|
|
| |
Length L | m | 2 x 2 = 4 | 2 x 2.5 = 5 | 2 x 2.5 = 5 | 2 x 3 = 6 | 2 x 3 = 6 | 2 x 3 = 6 | 2 x 3 = 6 | |
Diameter D1/D2 | mm | 40/48 | 40/48 | 40/48 | 40/48 | 40/48 | 48/60 | 48/60 | |
|
|
|
|
|
|
|
|
| |
Cable entry points |
| 3 | - | 3 | - | 3 | 5 | 5 | |
|
|
|
|
|
|
|
|
| |
Grade (steel) |
| St. 52 | St. 37 | St. 52 | St. 37 | St. 52 | St. 52 | St. 52 | |
|
|
|
|
|
|
|
|
| |
Wall thickness in | mm | 2.5 | 2 | 2.5 | 2 | 2.5 | 2.5 | 4.5 | |
clamping range | |||||||||
|
|
|
|
|
|
|
| ||
Perm. bending moment ¹), | 5.0 m | - | - | - | 320 | 850 | 1,150 | 1,950 (1,150) | |
4.0 m | - | 500 | 1,040 | 430 | 960 | 1,280 | 2,120 (1,280) | ||
useful length at 800 N/m² | |||||||||
3.0 m | 1,170 | 540 | 1,080 | - | - | - | - | ||
| |||||||||
Perm. bending moment ¹), | 5.0 m | - | - | - | 160 | 700 | 900 | 1,700 (900) | |
4.0 m | - | 390 | 920 | 300 | 840 | 1,080 | 1,960 (1,080) | ||
useful length at 1,100 N/m² | |||||||||
3.0 m | 1,110 | 480 | 1,000 | - | - | - | - | ||
| |||||||||
Packing unit/weight | pc./kg | 1/11.4 | 1/11.3 | 1 (25)/14.2 | 1 (25)/13.1 | 1 (25)/17.8 | 1 (25)/20.5 | 1/35.0 | |
|
|
|
|
|
|
|
|
|
¹) The max. perm. bending moment at the fixing point applies to the useful length. The windload of the mast has already been considered. According to EN
²) The technical data are based on DIN 4131. If the calculated bending moment exceeds the values given in brackets (= 1,650 Nm on the clamping point), static proof is required, acc. to EN
Internet: www.kathrein.de
935.434/C/0108/8.8d/e/ZWT Subject to technical changes.