Keating Of Chicago 022770 manual Removal And Replacement Of Thermopile

Models: 022770

1 2
Download 2 pages 28.08 Kb
Page 2
Image 2
REMOVAL AND REPLACEMENT OF THERMOPILE

S E R V I C E I N S T R U C T I O N S

www.keatingofchicago.com

1-800-KEATING

REMOVAL AND REPLACEMENT OF THERMOPILE

FOR AA, AAHI & CM FRYERS

PART #022770*

REMOVAL:

1.Unscrew and remove thermopile bulb from bracket.

2.Unscrew thermopile capillarys from millivolt gas valve.

REPLACEMENT:

1.Uncoil new thermopile carefully.

2.Install connectors on the thermopile to the millivolt gas valve. (as shown in wiring diagram.)

a.One connector goes to the TP screw on the millivolt control valve.

b.The other connector goes to the TH-TP screw on the millivolt control valve.

NOTE: THESE ARE SCREW CONNECTORS

*THIS THERMOPILE PART #022770 REPLACES THE THERMOPILE PART #002567.

Ø29740

REVØ

ECO#1862 10/21/97

11-99

REPTHERM