Keating Of Chicago 055173 installation instructions Flexible Tubing to Hard Piping Installation

Models: 055173

1 2
Download 2 pages 9.6 Kb
Page 1
Image 1
S E R V I C E I N S T R U C T I O N S

S E R V I C E I N S T R U C T I O N S

Part No. 057122

www.keatingofchicago.com1-800-KEATING

Flexible Tubing to Hard Piping Installation

Instructions – for Motor/Pump Part# 055173

Page 1 of 2

Operation #1 Dis-Assembly

Motor/Pump

Filter Tub Assembly

See Note #1

Housing Covers

 

See Note #5

 

(2X)

 

Motor/Pump

 

Housing Assembly

Filter Tub Assembly in Unlocked Position

90° Compression

Filter Cart Frame Assembly

Fitting See Notes

 

#3 and #5

 

View “A – A”

 

 

Pull Rod

 

Bracket SE Coupler

 

See Note #4

See Note #2

Compression Fitting

 

 

See Note #3

 

Caution:

Make Sure Saftey Glasses are Worn

Notes:

1.Drain and clean all oil from filter tub assembly. Remove filter tub assembly from filter cart frame assembly. This assembly will be turned over (upside down), for replacement of parts and adjustment to mating part on motor mount housing assembly.

2.Remove pull rod and set aside; this part will be used later.

3.Loosen compression fitting at pump output. Do not remove 90° fitting from pump.

4.Remove (4) bolts holding bracket SE coupler. This assembly will be replaced with new parts in kit. The bracket and flex tubing with quick connect are to be discarded.

5.Inspect 90° compression fitting on the pump as shown in View A – A. If the fitting is not on center line of the radius on the pump mount housing assembly as shown, use a #23 or #24 drill to remove pump housing covers (2) as shown in view A – A, to gain easier access to the top bolts holding the motor/pump. Loosen (4) bolts on motor/pump to center 90° fitting as best as possible. These covers will be re-assembled with parts in the kit. After adjustments are made to the motor/pump to center 90º compression fitting as shown in view A – A, tighten the (4) bolts for the motor/pump.

Use these Service Instructions for the following Kit part #’s:

 

057117

SE14

 

057118

SE18

057119

SE20

057120

SE24

HardPiping057122.qxd