18 AA GAS
18 AA GAS
RECOVERY® FRYER
The Keating Instant Recovery® 18 AA Fryer consists of a frying vessel 18" sq., having a splash deck and a splash back installed in a cabinet equipped with gas burners and an automatic temperature control mechanism, all arranged and designed for the proper frying of food.
SPECIFICATIONS:
Frying Vessel: shall be constructed from 18 gauge stainless steel, shall have a shortening capacity of 68 pounds, shall be equipped with four 18 gauge horizontal heat transfer tubes spaced above the bottom of the vessel so that the bottom is unheated and the food particles collecting in this bottom zone are unheated and therefore do not carbonize. The frying vessel shall be polished to inhibit carbon
Splashdeck shall slope toward the shortening containing vessel. The splash deck shall be made of 16 gauge 304 stainless steel.
Splashback shall be made of 18 gauge 304 stainless steel, shall completely cover the sides of the flue.
Cabinet: shall be made of 18 gauge stainless steel. The cabinet shall be rigid in construction and shall have four 8" adjustable legs. A door made of 22 gauge 304 stainless steel shall cover the front of the cabinet and shall extend from the bottom of the fryer to the panel, and above the panel shall be a canopy. The door shall be the full width
of the cabinet. No additional space is required for the door to open a full 90 degrees. A stainless steel flue deflector is to be provided for installing onto flue back.
Heat Transfer Tubes to be four, made of stainless steel polished to a #7 mirror finish.
Thermostat shall be close range, hydraulic type and be accurate to ±3°F from 300° to 350°F with stainless steel bulb. Application of this thermostat is patented by Keating.
100% Safety Shut Off shall be millivolt type with combination control gas valve and thermopile.
Standard Accessories to include one pair 4 mesh baskets, grid screen over heat transfer tubes, drain clean out rod and sample of Keating Klenzer and Sea Powder.
Electrical Requirements are not necessary on AA models.
Gas Requirements to install are 3/4" male NPT connection and 4" water column pressures natural and 10" for LP gas at the fryer burner manifold. Supply pressure to fryers must be 7" (natural gas) and 11" (LP) water column.
Special Order Options may include battery, common manifold, rear drain, casters, cover, thermostat seal, portable filter, central filter (CF18SE), Safe & Easy® filter, full or triple size baskets, security package, 2" drain valve (not available on SE), and 17" flue riser.
INSTANT
|
|
| Oil | BTU |
|
|
|
| Ship |
|
|
Model No. and Description | Capacity | Input | Height | Depth | Width | Wt. |
|
| |||
|
|
|
|
|
|
|
|
|
|
| |
18 | AA Nat Gas | 68 lbs. | 134,000 | 46 1/2" | 32 1/2" | 19 3/8" | 210 lbs. |
|
| ||
|
|
|
|
|
|
|
|
|
|
| |
18 | AA LP Gas | 68 lbs. | 132,000 | 46 1/2" | 32 1/2" | 19 3/8" | 210 lbs. |
|
| ||
|
|
|
|
|
|
|
|
|
|
| |
18 | Safe & Easy | - | - | 46 1/2" | 38 5/8" | 19 3/8" | - |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
KEATING OF CHICAGO, INC. Toll Free
As continuous product improvement occurs, specifications may be changed without notice.
Printed in U.S.A. | 18AA2007 | 7/07 |