Temperature Controller Manual

Temperature Controller Manual

Feature of Function

This temperature controller adopt world well‐ known brand SCM. It is reliable and durable. The relay is exclusively used for compressor loads which make it safer. The way of controlling temperature is return type and easy to operate.

Mine‐sized and integrated intelligent control, it is applicable to the compressor of one H.P. Suit for a ventilated freezer.

Main functions

Temperature display (Celsius/Fahrenheit degrees)

Temperature control

Evaporator fan control (parallel with compressor or continuous running changes)

Manual, automatic defrost by electric heater

Time or temperature setting to end defrost

The cold‐room sensor temperature can lock during defrost

Parameter locking

The factor default resumption

Offset on sensor temperature

Self testing

Specification

Power supple: 12V ~, 50/60Hz; Power

consumption: < 5W

Range of temperature displayed:‐ 45~45 C

(‐40~120 F)

Range of set temperature: ‐45~45 C

(‐40~120 F)

Temperature sensor: NTC, double sensor.

Output contact capacity for compressor: N.O. 20A/250V~; 50/60Hz. The inrush current for compressor control may be 20A instead of 8A during the period of 1s at start. (applicable to 1 H.P. compressor if more connected to AC contactor)

Output contact capacity for Evap. Fan: N.O. 20a/250V~; 50/60Hz.

Main controller panel dimension 78X35X76mm. Mounting dimension: 71:29mm

Indicator

Refrigerant: When the refrigerant LED is on, the compressor is working.

Constant temperature: When the refrigerant LED is off, the compressor has stopped.

Delay: When the refrigerant LED flashes, the compressor stops.

Defrost: When the defrost LED is on, the compressor and fan stop and the heater works.

Evaporator fan: When the fan LED is on, the fan is working.

Front Panel Operation

Set temperature: Press Feature of Function button, the set temperature is displayed; Press or button to modify and store the displayed value, press Main functions button to exit the adjustment and display the cold‐room temperature.

Manual start/stop defrost: Press Specification button and hold for 6 seconds to defrost or stop defrost.

Display the evaporator temperature: Press Indicator button and hold for 6 seconds. The evaporator temperature will be displayed. After 10 seconds, the cold‐room temperature is resumed to be displayed.

Parameter Setup

Indication for setting parameter: The parameter can be adjusted only after correct PA has been entered. All parameters can only be checked,

6

Page 6
Image 6
Kelvinator KCBM48R, KCBM72R Temperature Controller Manual, Feature of Function, Main functions, Specification, Indicator