Recessed area or closet installation
The dimensions shown are for the recommended spacing allowed, except the closet door ventilation openings. The dimensions shown for the closet door ventilation openings are the minimum required.
123
1.Front view
2.Side view
3.Closet door with vents
•Additional spacing should be considered for ease of installation and servicing.
•Additional clearances may be required for wall, door and floor moldings.
•Additional spacing of 1 in. (2.5 cm) on all sides of the washer is recommended to reduce noise transfer.
If a closet door is installed, the minimum air openings in the
top and bottom of the door are required. Louvered doors with air openings in the top and bottom are acceptable.
Companion appliance spacing should also be considered.
The washer can be installed using the standpipe drain system (floor or wall), the laundry tub drain system, or the floor drain system. Select the drain hose installation method you need. See "Alternate Parts."
U =
(m©m)
2
Standpipe drain system - wall or floor (view I & 2)
The standpipe drain requires a minimum diameter standpipe of 2 in. (5 cm). The minimum
The top of the standpipe must be at least 39 in. (99 cm) high and no higher than 96 in. (244 cm) from the bottom of the washer.
Laundry tub drain system (view 1)
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top of the laundry tub must be at least 39 in. (99 cm) above the floor
and no higher than 96 in. (244 cm) from the bottom of the washer.
Floor drain system (view 2)
The floor drain system requires a siphon break that may be purchased separately. See "Alternate Parts."
The siphon break must be a minimum of 28 in. (71 cm) from the bottom of the washer. Additional hoses might be needed.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
A
This washer is equipped with a power supply cord having a 3 prong grounded plug.
To minimize possible shock hazard, the cord must be
plugged into a mating, 3 prong,