The angled hood style (shown here) is acceptable.
4"
(10.2 cm)
2½" (6.4 cm)
■An exhaust hood should cap the vent to keep rodents and insects from entering the home.
■Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, snow line, etc.).
■Do not use an exhaust hood with a magnetic latch.
Improper venting can cause moisture and lint to collect indoors, which may result in:
Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc.
Housecleaning problems and health problems.
Plan Vent System
Choose your exhaust installation type
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer. Other installations are possible.
| B |
| C |
| D |
A | E |
| F |
| G |
| H |
A. Dryer | E. Clamps |
B. Elbow | F. Rigid metal or flexible metal vent |
C. Wall | G. Vent length necessary to connect elbows |
D. Exhaust hood | H. Exhaust outlet |
Optional exhaust installations
This dryer can be converted to exhaust out the right side, left side, or through the bottom. Contact your local dealer to have the dryer converted.
WARNING
Fire Hazard
Cover unused exhaust holes with one of the following kits:
279818 (white)
279915 (black diamond)
280102 (pacific blue)
280103 (champagne)
280189 (barolo)
Contact your local dealer.
Failure to follow these instructions can result in death, fire, electrical shock, or serious injury.
ABC
A. Standard rear offset exhaust installation B. Left or right side exhaust installation
C. Bottom exhaust installation (not an option with pedestal installations)
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best for your installation. Two
AB
A.
NOTE: The following kits for close clearance alternate installations are available for purchase. For further information, please call
15