Closet installation - Dryer only

 

 

 

 

 

3"*

 

 

14" max.*

 

(7.6 cm)

 

 

(35.6 cm)

48 in.2*

 

 

 

 

(310 cm2)

 

 

18" min.*

 

 

 

(45.72 cm)

 

 

 

 

 

24 in.2*

 

 

 

 

(155 cm2)

3"*

 

 

 

 

(7.6 cm)

1"*

31½"

5"**

 

 

(2.5 cm)

(80 cm)

(12.7 cm)

 

 

AB

A. Side view - closet or confined area

B. Closet door with vents

*Required spacing

**For side or bottom venting, 0" (0 cm) spacing is allowed.

Recessed or closet installation - Dryer on pedestal

Recommended installation spacing for recessed or closet installation, with stacked washer and dryer

The dimensions shown are for the recommended spacing.

48 in.2 *

(310 cm2)

3"* (7.6 cm)

 

3"* (7.6 cm)

24 in.2 *

1"* (2.5 cm)

(155 cm2)

 

*Required spacing

6"* (15.2 cm)

1"

 

 

 

 

 

27"

 

 

(2.5 cm)

 

 

(68.6 cm)

14" max.*

(35.6 cm)

18" min.*

(45.72 cm)

 

1"

 

1"*

 

 

31¹⁄₂"

 

 

5"**

 

 

 

 

 

 

 

(2.5 cm)

(2.5 cm)

(80 cm)

 

(12.7 cm)

76" (193 cm)

5"*

 

 

 

1"

 

 

 

27"

 

1"

 

 

 

 

 

(12.7 cm)

 

 

(2.5 cm)

 

 

(68.6 cm)

(2.5 cm)

AB

A. Recessed area

B. Side view - closet or confined area

*Required spacing

**For side or bottom venting, 0" (0 cm) spacing is allowed.

Installation spacing for cabinet installation

For cabinet installation, with a door, minimum ventilation openings in the top of the cabinet are required.

7"* (17.8 cm)

7"* (17.8 cm)

9"*

(22.9 cm)

5"**

31¹⁄₂"

1"*

1"

27"

1"

(12.7 cm)

(80.0 cm)

(2.5 cm) (2.5 cm)(68.6 cm) (2.5 cm)

*Required spacing

**For side or bottom venting, 0" (0 cm) spacing is allowed.

*Required spacing

Mobile home - additional installation requirements

This dryer is suitable for mobile home installations.

The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280).

Mobile home installations require:

Metal exhaust system hardware, which is available for purchase from your local Sears store or Sears Service Center.

Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.