Troubleshooting (continued)

Burner(s) will not light

ELECTRONIC IGNITION:

using ignitor.

No

spark,

no ignition noise.

(See Electronic

 

 

 

 

Ignition

No

spark,

some ignition noise.

Troubleshooting also)

 

 

 

 

Sparks, but not at electrode or at full strength.

Burner(s) will not

See "GAS

ISSUES:" on previous

match light.

 

page.

 

 

• Match wiii not reach.

 

Improper

method of match-iighting.

Suddendrop ingas • Out of gas. flow or tow flame.

See Section I of Electronic Ignition System.

See Section II of Electronic Ignition System.

See Section III of Electronic Ignition System.

• Use long-stem match

(fireplace

match).

See "Match-Lighting"

section of

Use and Care.

Check for gas in LPcylinder.

 

• Turn off knobs, wait 30 seconds and light grill. If flames are

Flames blow out.

Flare-up.

Excess flow valve tripped.

Vapor lock at coupling nut/LP cylinder connection.

High or gusting winds.

Low on LP gas.

Excess flow valve tripped.

Grease buildup.

Excessive fat in meat.

Excessive cooking temperature.

still low, turn off knobs and LPcylinder valve. Disconnect

regulator. Reconnect regulator and leak-test. Turn on LP

cylinder valve, wait 30 seconds and then light grill.

• Turn off knobs and LPcylinder valve. Disconnect coupling nut

from cylinder. Reconnect and retry.

• Turn front of griii to face wind or increase flame height.

• Refill LPcylinder.

• Refer to "Sudden drop in gas flow" above.

• Clean burners and inside of grili/firebox.

• Trim fat from meat before grilling.

• Adjust (lower) temperature accordingly.

Persistent grease fire. • Grease trapped by food buildup around burner system.

Flashback...

 

Burner

and/or

burner

tubes

are

(fire in burner

tube(s))

 

blocked.

 

 

 

 

Unable to fill

LP

Some dealers have older

fiiI nozzles

cylinder,

 

with worn

threads,

 

 

 

One burner does

Grease

buildup or food

particles

in

not light from

 

 

end (s) of

carryover

tube (s).

 

other burner (s).

 

 

 

 

 

 

• Turn knobs to OFF. Turn gas off at LPcylinder. Leave lid in

position and let fire burn out. After grill cools, remove and

clean ait parts.

• Turn knobs to OFF. Clean burner and/or burner tubes. See

burner cleaning section of Use and Care.

• The worn nozzles don't have enough "bite" to engage the

valve. Try a second LPdealer.

• Clean carry-over tube (s) with wire brush.

16132-40200104 • 27

Page 27
Image 27
Kenmore 146.1613211, 146.1613311 manual Suddendrop ingas Out of gas. flow or tow flame, Electronic Ignition