5A. TROUBLESHOOTING

Keep this manual with your water softener. If repairs are needed, the service technician must have
the information on the following pages For telephone assistance, call toll free, 1-800-426-9345
1}0
VAC
TRANSFORMER
24VAC
(

iWIRtNG SCHEMATIC

wh
gm
__ Shield
i .... ITURBINE
"-'--"'SENSOR
NC
0"*"_"_POSITIO NSWITCH
-0
NO
display J
DemandWaterSoftener
ON/OFF-HOLD button
(Recharge Tonight-Now) SELECT button DOWN
button
ALWAYS MAKE THESE INITIAL CHECKS FIRST
1. Does the time display show the correct time ofday?
If display is blank, check power source to the
softener,
- Iftime is flashing, power was off' for over 6 hours The
softener resumes no[maI operation but regenerations
occur at the wrong time,
- If an error code (Example: Err 03) shows in the face
plate display, go to Automatic Electronic DiagnostiCs
2. Plumbing bypass valve(s) must be in Full Service
position.
3_
4_
The inlet and outlet pipes must connect to the softener
valve inlet and outlet respectively
Is the transformer plugged into a "live", grounded wall
outlet, and isthe power cable fastened securely?
5. The valve drain hose must be free of kinks and sharp
bends, and not elevated over 8 ft. above the floor'
REMOVETHETOP COVER ANDSALTTANKCOVER
6. Is there salt in the storage tank?
7. Is the brine tubing connected? (See water' flow
diagrams),
8. Is the brine valve float set right? (See page 22)
9. Press the SELECT button 2 times to display the hardness
setting Be sure it is the correct setting for the
househotd's water supply, (Make a hardness test of the
raw water' and compare with the hardness setting, Also
test a soft water' sample to verify if a problem exists,)
Press SEIECT twice more to return the time of day
display.
If you do not find the problem after' making initial checks,
do the Manual Initiated Electronic Diagnostics, and the
Manual Advance Regeneration Check,
19