SECTION 2
HOW YOUR WATER SOFTENER WORKS
2A.FACEPLATE TIMER FEATURES
OPTIONAL SETTINGS- CLEAN FEATURE
WATER FLOW THROUGH THE SOFTENER
MINUTES, MAXIMUM DAYS BETWEEN REGEN- ERATIONS, and 12 / 24 HOUR TIME READINGS:
1.To set 1, 2 or all 3 options, press and hold SELECT for 3 seconds. Then press again until the CLEAN TIME display shows.
MIN |
|
|
|
CLEAN |
|
|
|
TIME | I | CLEAN | 3 MIN |
| |||
|
|
| TIME |
default minutes | example: | time set to 3minutes |
If soft water is in use, the water
flow bars continually scroll
across the display. The bars scroll slowly when water flow
is slow, and move faster as
water flow increases. The flow
bars do not show when all
faucets and water using ap-
pliances are off.
I'uO
IOFI q,N 13_
WATER FLOW
no water flow
I'UI]
i °F]
#_ WATER FLOW
/
Flow bars scroll when soft water is in use.
_CLEAN | feature | minutes: | If | you | are | using | this | ||
feature | (page | 7), the length | of | the | extra | backwash | |||
cycle | automatically | sets | to 7 | minutes. | However, | ||||
you | can | adjust | this | time | from | 1 to 15 | minutes | in |
length. To change this cycle time, use the UP button
to increase the time, or the DOWN button to
shorten the time. If no change is desired, continue below.
2. Press SELECT again to show the following
RECHARGE display.
default display | example: set to 4 days maxi- |
| mum between regenerations |
_Maximum days between regenerations: The
faceplate timer automatically controls regenera-
tion frequency (see page 14). This provides the
greatest operating efficiency, and normally the
maximum days feature is not needed. If you want to
be certain a regeneration will occur within a
number of days, use this feature. For example, if
your water supply contains iron and you want the
softener to regenerate at least once every few days
to keep the resin bed clean, set the display as
typically shown above. Setting is available from 1
to 15 days by using the UP and DOWN buttons.
RECHARGE TIME REMAINING and VALVE
POSITION |
| INDICATORS |
|
| valve | recharge | |||||
One | of the valve | position |
| indi- | position |
| time | ||||
cators | (Serv, | Fill, | Brine, | Bkwsh, | indicators | remaining | |||||
|
| ||||||||||
Rinse) | is | displayed |
| while | the | _oF_ |
|
| |||
*NOTE | on | page | 10 | if | the | i | _,i | RET'_g_EgA"'_ | |||
softener |
| is | recharging | ON). | (See | ||||||
CLEAN | feature | is | RE- |
|
|
|
| ||||
CHARGE flashes in the display |
|
|
|
| |||||||
and, | beginning | with | Brine, | the minutes | of recharge | ||||||
remaining | before | return | to service appears in place | ||||||||
of the present time. When the valve is moving from | |||||||||||
one cycle | to | another, | both | position |
| indicators | are | ||||
flashing. |
|
|
|
|
|
|
|
|
|
|
PROGRAM MEMORY
If electrical power to the softener goes off, the time
display is blank but the face plate timer keeps the
correct time for about 12 hours. When electrical
power comes on again, you have to reset the
present time only if the display is flashing. The
HARDNESS and RECHARGE TIME never require
resetting unless a change is desired.
Even if the timer is incorrect after a long power
outage, the softener works as it should to keep
your water soft. However, regenerations may occur at the wrong time of day until you reset the
3. Press SELECT to show the 12 HOUR
_12 or 24 hour clock: All time
displays are shown in standard clock time (1 to 12 PM; and I to 12 AM) at the 12 hr default
setting. If military time dis- plays are desired, set to 24 hr by
pressing the UP button.
display.
I _WhF _;
TIME
2clhc
TIME
timer to the correct time of day.
ERROR | CODE |
|
|
|
|
|
| |||
An | error |
| code | could | appear | in | F I | |||
the | face plate | display | if a prob- |
|
|
| ||||
lem | occurs | in | the | softener | elec- |
|
| |||
tronics. | If you | see | an | error | code |
|
|
| ||
instead | of | the | present | time | of | day, | please call | your | ||
local | Sears | Service | Department | for | service. |
|
4. Press SELECT to return the present time display.