Kenmore W10192868A, 10646033800 manual Performance Data Sheet, Base Grille Water Filtration System

Models: 10646032800 10645439801 10646022801 10646029800 10645432801 10645429800 10645432800 10645423800 10646033801 10646033800 W10192868A

1 40
Download 40 pages 58.93 Kb
Page 11
Image 11
PERFORMANCE DATA SHEET

PERFORMANCE DATA SHEET

Base Grille Water Filtration System

Model T1 KB1/T1 RFKB1 Capacity 100 Gallons (379 Liters)

System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of

Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSI Standard 53 for the reduction of

Lead, Mercury, Atrazine, Benzene, Toxaphene, O-Dichlorobenzene, Cysts, Turbidity, Asbestos, Lindane,

Tetrachloroethylene, Endrin, Alachlor, Chlorobenzene, Ethylbenzene, TTHM, MTBE and VOC.

This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.

Substance

Reduction

NSF Reduction

Average

Influent

Challenge

Maximum

Average

Minimum

%

Average

%

Aesthetic

Effects

Requirements

Influent

 

Concentration

Effluent

Effluent

Reduction

 

Reduction

Chlorine

Taste/Odor

50%

reduction

2.0

mg/L

2.0 mg/L

+ 10%

0.08

mg/L **

2.0 mg/L

95.93

 

97.36

 

Particulate

Class I*

85%

reduction

3533333#/mL

At east

10,000 part c es/mL

22000

#/mL

11567

#/mL

99.38

 

99.67

 

Contaminant

 

NSF Reduction

Average

 

Influent

Challenge

Maximum

Average

Minimum

%

Average

%

Reduction

 

 

Requirements

Influent

 

Concentration

Effluent

 

Effluent

 

Reduction

 

Reduction

 

Lead: @ pH 6.5

0.010

mg/L

150 ug/L

0.15

mg/L

+ 10%

1.0

ug/L

1 ug/L

 

99.33

 

99.33

 

Lead: @ pH

8.5

0.010

mg/L

157 ug/L

0.15

mg/L

_+10%

2.0

ug/L

1.08

ug/L

98.72

 

99.31

 

Mercury:

@ pH 6.5

0.002

mg/L

0.0058

mg/L

0.006

mg/L

+ 10%

0.0002

mg/L

0.0002

mg/L

96.53

 

96.53

 

Mercury:

@ pH 8.5

0.002

mg/L

0.0057

mg/L

0.006

mg/L

_+10%

0.0002

mg/L

0.0002

mg/L

96.5

 

96.5

 

Benzene

 

 

0.005

mg/L

15 ug/L

 

0.015

mg/L

_+10%

0.5

ug/L

0.5

ug/L

96.67

 

96.67

 

O-Dichlorobenzene

0.6 mg/L

1750 ug/L

1.8 _+10%

 

1.0

ug/L

1.0

ug/L

99.94

 

99.94

 

Toxaphene

 

0.003

mg/L

15 ug/L

 

0.015

_+10%

1.0

ug/L

1.0 ug/L

93.33

 

93.33

 

Atrazine

 

 

0.003

mg/L

10 ug/L

 

0.009

mg/L

_+10%

2 ug/L

 

2 ug/L

 

80.8

 

80.8

 

Asbestos

 

 

99%

 

101 MFL

107to

108fibers/U t

0.17

MFL

0.17

MFL

99.83

 

99.83

 

Live Cysts _

>99.95%

120,000/L

50,000/L

min.

8/U

 

 

1/U

 

 

99.99

 

>99.99

 

Turbidity

 

 

0.5 NTU

11.4

NTU

11 _+1 NTU

0.41

NTU

0.24

NTU

96.4

 

97.89

 

Alachlor

 

 

0.002

mg/L

41.3

ug/L

0.04

_+10%

 

0.2

ug/L

0.2 ug/L

99.52

 

99.52

 

Endrin

 

 

0.002

mg/L

5.9

ug/L

0.006

_+10%

0.5

ug/L

0.3

ug/L

91.5

 

95.47

 

Ethylbenzene

0.7 mg/L

1867 ug/L

2.1 _+10%

 

0.70

ug/L

0.0588

ug/L

99.96

 

100

 

Lindane

 

 

0.002

mg/L

1.9

ug/L

0.002

_+10%

0.02

ug/L

0.02

ug/L

98.93

 

98.93

 

Chlorobenzene

0.6 mg/L

2.0

ug/L

2.0 _+10%

 

0.0005

ug/L

0.0005

ug/L

99.98

 

99.98

 

Tetrachloroethylene

0.005

mg/L

14.2 ug/L

0.015

_+10%

0.5

ug/L

0.5

ug/L

96.47

 

96.47

 

TTHM

 

 

0.080

mg/L

465

ug/L

0.45

_+20%

 

1.0

ug/L

0.5

ug/L

99.78

 

99.88

 

MTBE

 

 

0.005

mg/L

14 ug/L

 

0.015

_+20%

0.70

ug/L

0.52

ug/L

94.94

 

96.27

 

V©C

 

 

0.015

mg/L

0.3520

mg/L

0.300

_+10%

0.0060

mg/L

0.0008

mg/L

98.4

 

99.78

 

Test Parameters: pH = 7.5 _+0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 100 gallons (379 liters).

It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.

Model TIKBI" The filter monitor system measures the amount of

water that passes through the filter and alerts you to replace the filter.

Style 1 - When the filter indicator reads 10%, order a new filter. When the filter indicator reads 0%, it is recommended that you replace the filter.

Style 2 - When the filter indicator light changes from green to yellow, order a new filter. When the filter indicator light changes

from yellow to red, it is recommended that you replace the filter.

Use replacement cartridge T1 RFKB1, part #9030. In Canada, use replacement cartridge T1 RFKB1, part #9030B. 2008 suggested retail price of $41.99 U.S.A./S51.99 Canada. Prices are subject to change without notice.

These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual performance may vary.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.

Refer to the front cover or "Accessories" section for the Manufacturer's name, address and telephone number.

Refer to the "Warranty" section for the Manufacturer's limited warranty.

 

Application

Guidelines/Water

Supply

Parameters

Water

Supply

City

or Well

 

Water

Pressure

30 - 120 psi (207 - 827 kPa)

Water

Temperature

33 ° - 100°F

(0.6 ° - 37.8°C)

Service

Flow Rate

0.5

gpm (1.9

L/min) @ 60 psi

The product is for cold water use only.

*Class I particle size: >0.5 to <1 um

**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust. ttFibers greater than 10 um in length

_Based on the use of Cryptosporidium parvum oocysts

® NSF is a registered trademark of NSF International.

11

Page 11
Image 11
Kenmore W10192868A, 10646033800, 10646033801, 10645423800 manual Performance Data Sheet, Base Grille Water Filtration System