Kentrox AAC-2TM, CELLSMART SLA Monitoring, Monitors up to 512 VCs, AAC-3, AAC-2 and CellSMART

Models: AAC-2TM CELLSMART AAC-3

1 12
Download 12 pages 52.83 Kb
Page 5
Image 5
AAC Service Data Module (SDM) Supports ATM Managed Services

AAC-3®, AAC-2and CellSMART®

AAC Service Data Module (SDM) Supports ATM Managed Services

The Service Data Module for the AAC acts

as a Visual Networks® Analysis Service Element (ASE). Specifically designed to support NxT1/E1 IMA or DS3/E3 ATM networks, it monitors user-specified ATM ports and circuits, and communicates service performance data and events to Visual UpTime®.

Kentrox and Visual Networks enable service providers to introduce WAN Performance Management Services based on industry-proven hardware and software solutions. Service providers can offer customers a variety of new managed service options and a higher degree of flexibility for hybrid ATM/Frame Relay networks.

Site 1

 

AAC-2 with

 

SDM Module

Frame Relay

 

on HSSI

ATM

 

IMA

Monitors up to 512 VCs

Monitors ATM traffic on user-specified ports and VCs, up to a maximum aggregate rate equivalent to a bi-directional DS3

Provides data for Visual UpTime Event Processor, Troubleshooting, and Planning and Reporting tool sets

Provides valuable bandwidth utilization details with protocol analysis and top host statistics

Sends SNMP traps regarding AAC events to Visual UpTime

Site 2

AAC-2 with

SDM Module

Frame Relay

on HSSI

ATM Public

ASE

T1

Network

Frame Relay

 

Public

 

Network

T1

 

ASE

ATM

T1

on DS3

ASE

Figure 4: AAC acting as an ASE for Visual UpTime.

SLA Monitoring

The Service Data Module for the AAC can be configured to supply Frame Relay Service Level Agreement (SLA) measurements to Kentrox ServicePointand FrameVisiondevices in ATM and Frame Relay mixed networks. The AAC responds to Frame PING messages (FPING) sent by ServicePoint and FrameVision devices delivering the following:

Round-trip Delay

End-to-end Delay

Frame Delivery Ratio

Data Delivery Ratio

Frames Dropped, Received and Transmitted

P

CBR on

B

DSX-1

X

Video

CBR on

V.35

 

Frame Relay

on HSSI

 

 

ServicePoint SDU

 

 

T1

IMA ATM Public

 

ServicePoint SDU

Network

Frame Relay

 

 

AAC-2 with

Public

T1

SDM Module

Network

 

 

 

T1

 

 

DataSMART Frame

 

 

Monitoring DSU/CSU

Figure 5: Providing SLA data by responding to FPING messages.

www.kentrox.com5 800.733.5511

Page 5
Image 5
Kentrox AAC-2TM, AAC-3 manual SLA Monitoring, Monitors up to 512 VCs, Sends SNMP traps regarding AAC events to Visual UpTime