Specifications

AAC-3®, AAC-2, and CellSMART®

Specifications

AAC-3 CHASSIS

Dimensions (H x W x D): 13.95” x 17.32” x 19” (354.3 x 440 x 482.6 mm)

Weight: 60 lbs. (27 kg)

Mounting: Available for 19-inch or 23-inch standard equipment racks

Operating Temperature: 32º F to 104º F, ambient (0° C to 40° C)

Operating Humidity: 5% to 95%, non-condensing

AAC-2 AND CELLSMART 200 CHASSIS

Dimensions (H x W x D): 6.95” x 17.32” x 19” (176.5 x 440 x 482.6 mm)

Weight: 29 lbs. (13.2 kg)

Mounting: Available for 19-inch or 23-inch standard equipment racks

Operating Temperature: 32º F to 104º F, ambient (0° C to 40° C)

Operating Humidity: 5% to 95%, non-condensing

EMI/ESD/SAFETY

EMI: FCC Part 68, FCC Part 15, Class A, EN55022 Class B

Immunity: EN55024

Safety: UL1950, EN60950, CSA 22.2 No 950 - M95

NEBS: Level 3 certified

SWITCHING BACKPLANE

Cell bus: Dynamic time-allocated, output buffered per port or connection

Maximum system throughput: 524 Mbps (1,168,000 cells/second)

Connections: 8192 VCCs, 512 VPCs, 512 Multicast

POWER SYSTEM

AAC-3:Dual redundant power system. Modular power supplies, field replaceable with unit powered. Monitored with alarms/traps on failure. Forced-air cooled. Supports mixed use of AC/DC power modules.

AAC-2 and CellSMART 200: Single power system. Modular power supply. Monitored with alarms/traps on failure. Forced-air cooled. Supports use of AC/DC power modules.

AC power supply modules: 120/240 VAC (85 to 264 volts), 50/60Hz +/- 3Hz

DC power supply modules: -48 VDC (42 to 60 VDC)

MANAGEMENT ACCESS

Control port: VT100 via RS232 port on front panel (Additional RS232 port on the Integrated System Controller)

Ethernet port: SNMP or Telnet

In-band:SNMP or Telnet

Telnet sessions: Up to 4 concurrently with the Integrated System Controller

Common Modules

INTEGRATED SYSTEM CONTROLLER (ISC)

Clock sources: Internal reference oscillator or recovered from user-specified physical port

Clock fallback: User-selectable primary and secondary clock source with automatic fallback and recovery

Internal reference: Oscillator Stratum 4 or better

Power loss protection: Loss of all input line power will not affect the configuration settings; performance data will be maintained for 12 hours upon loss of power

Alarm: Critical, Major, and Minor alarm indicators are viewable from the rear Contact closure for audible and visual alarms

ACO (Automatic Cut Off) button disables audible alarms Configuration backup: Pluggable Type II compact flash

Management access: Ethernet port and DTE asynchronous port for dial-up modem (in addition to front panel port)

www.kentrox.com6 800.733.5511

Page 6
Image 6
Kentrox Specifications, Common Modules, AAC-3, AAC-2, and CellSMART, AAC-3 CHASSIS, AAC-2 AND CELLSMART 200 CHASSIS