In case of difficulty

CD-206/204/203/DPF-R6010/R4010/R3010 (En)

 

What appears to be a malfunction may not always be serious. If your unit should not perform as expected, consult the table

 

below to see if the problem can be corrected before seeking help from your dealer or service representative.

25

 

Operation to reset

The microcomputer may malfunction (impossibility to operate, erroneous display, etc.) when the connection cords are unplugged while the unit is ON or due to an external factor. In this case, execute the following method to reset the microcomputer and return it to normal condition.

Unplug the power cord from the power socket and plug the power cord into the socket again.

÷Please be aware that resetting the CD player will erase all stored information and return it to the factory settings.

CD player unit
Symptom
Cause
Remedy

 

 

 

 

The unit is not turned ON with the ON/

÷Power plug is loosely connected.

÷Insert the power plug firmly to the AC outlet.

STANDBY (POWER/

 

 

) switch ON.

÷With the power plug connected to the switched

÷Turn the amplifier’s power ON.

 

 

 

 

 

 

 

AC outlet of an amplifier, the power of the

 

 

 

 

 

 

amplifier is turned off.

 

 

 

 

 

There is no sound even when a disc is loaded.

÷Disc is loaded upside down.

÷Load the disc again with its label side up.

 

 

 

 

÷Disc is loose.

÷Insert disc properly.

 

 

 

 

 

÷Disc is dirty.

÷Wipe off the dust on the surface of the disc

 

 

 

 

 

referring to “Disc handling precautions”.¢

 

 

 

 

÷Disc is cracked.

÷Replace the disc with a new one.

 

 

 

 

 

÷Condensation has occurred on the optical lens

÷Remove any condensation from the unit by

 

 

 

 

unit.

referring to the section entitled, “Caution on

 

 

 

 

÷Play mode is not entered.

condensation”.

¢

 

 

 

 

÷Press the 6 key.

 

 

 

 

 

÷The connection cords are inserted loosely.

÷Connect all connection cords firmly.

 

 

 

 

 

÷Output level is attenuated too low.

÷Adjust the output level with OUTPUT key on

 

 

 

 

 

the remote control unit.

5

 

 

 

Music is interrupted. (Sound is skipped.)

÷Disc is too dirty.

÷Wipe off the dust on the disc surface referring

 

 

 

 

 

to “Disc handling precautions”.

¢

 

 

 

 

÷Disc is cracked.

÷Replace the disc with a new one.

 

 

 

 

 

÷Oscillation is applied to this unit.

÷Try selecting a place where no strong vibrations

 

 

 

 

 

occur by changing the installation place, etc.

 

 

 

Play begins as soon as the unit is turned ON.

÷This unit is designed so that play begins auto-

÷If automatic play is not required remove the

 

 

 

 

matically when the unit is turned ON if a disc is

disc from the player before setting the unit to

 

 

 

 

already loaded.

STANDBY mode.

 

 

 

 

 

 

 

 

Remote control unit

Symptom

Cause

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remedy

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote control operation is not possible.

÷Batteries are exhausted.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

÷Replace with new batteries.

8

 

 

÷The remote control unit is too far away from the

 

÷Operate the remote control unit

within the

 

main system, controlling angle is too large, or

 

 

controllable range.

8

 

 

there is an obstacle in between.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For the U.S.A.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KENWOOD CORPORATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Use of controls or adjustment or performance of procedures other than

2967-3, ISHIKAWA-CHO, HACHIOJI-SHI,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOKYO, JAPAN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

those specified herein may result in hazardous radiation exposure.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KENWOOD CORP. CERTIFIES THIS EQUIPMENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In compliance with Federal Regulations, following are reproductions of

 

CONFORMS TO DHHS REGULATIONS NO. 21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

labels on, or inside the product relating to laser product safety.

 

CFR 1040.10, CHAPTER I, SUBCHAPTER J.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Location: Back Panel