Controls
x 15W – 40W
Class D Mono
40
p q r s | t |
1Fuse (40 A × 1)
NOTE
If you can’t find the specified capacity fuse at your store etc., consult your Kenwood dealer.
2Battery terminal
3Ground terminal
4Power control terminal
Controls the unit ON/OFF.
NOTE
Controls the unit power. Be sure to connect it with all the systems.
5Speaker output terminals
As this unit accepts speakers with a minimum impedance of 2 ohms, connect speakers with
2CAUTION
The rated input of the speakers should be no less than the maximum output of the amplifier. Otherwise malfunction may result.
6BASS BOOST LEVEL control
Sets the low frequency level to be compensated.
7LPF(Low-Pass Filter) FREQUENCY control
This control adjusts the frequency band output from this unit.
8ISF (infrasonic filter) switch
Ultralow frequencies that cannot be reproduced even by a subwoofer speaker do not become sound but become unnecessary oscillations, which affect the sound by causing distortion, etc. Setting this switch to "15 Hz" or "25 Hz" cuts the frequencies below the respective frequency.
This improves the reproduction performance of the speakers by eliminating unnecessary oscillations which will not become sound.
9INPUT SENSITIVITY control
Set this control according to the
Use the diagram on the right as a guide.
NOTE
For the
u v w x y z {
0Speaker level input terminals
NOTE
•The
•Do not connect the speaker output leads from a power amplifier (Optional) to the speaker level input terminals of this unit, for this may cause malfunction or damage.
•Do not connect cables and leads to both RCA cable input jacks and the speaker level input terminals simultaneously, for this may cause malfunction or damage.
•Connect the power control lead to a power supply which can be turned ON/OFF by the ignition key switch (ACC line). With this connection, shock noise may be generated when the power of the
!LINE IN terminal
@LINE OUT terminal
The signal that’s input from the line input terminal is output.
#Power indicator
When the power is turned on, the Power indicator lights.
If the Power indicator does not light when the power is turned on, the protection function may be activated. Check whether there is any indication of trouble. (See page 2)
English 5