English | 27
Select the Font Color
Push the Control knob to [4] or [¢].
7 Exit display control mode
Press the [6] ("RTN") button.
Function of the KDC-X889/KDC-MP828/KDC-
MP7028/KDC-MP728/KDC-X789 Display Type E
G-Analyzer display Switching
Switches G-Analyzer display when the Display
type is set to "Display Type E". (G: gravity)
• Before switching G-Analyzer display, <G-Counter Level
set> (page 44) and <G-Analyzer Calibration set> (page
44) are required to be setup.
1 Select the key function section
Press the [NEXT] button.
Repeatedly press the button until "DISP" is
displayed above the [6] (KDC-X889/MP828)/[2]
(KDC-MP7028/MP728/X789) button.
Refer to <Notes on Multi-function Key System>
(page 9).
2 Enter display control mode
Press the [6]/[2] ("DISP") button.
3 Select the display mode
Press the [1] ("MODE") button.
4 Select the display Type
Push the Control knob to [4] or [¢].
Select the "Display Type E" display.
5 Enter G-Analyzer display select mode
Press the [3] ("GMENU") button.
6 Select the G-Analyzer display
Push the Control knob to [4] or [¢].
G-Force Sensor display
G- Graphic display
G-Meter display
(Graphic)
G-Meter display
(Text)
Point
Time
G-Counter display
• G-Graphic display
Displays the condition of G on horizontal direction
(e.g; when turning the curve) by the graphic.
• G-Meter display (Graphic)
Displays the maximum value of acceleration G, right
direction G, and left direction G by the numerical
value.
• G-Meter display (Text)
The maximum value of acceleration G, right direction
G, and left direction G is displayed by the numerical
value. The value of G is only the reference so it is
differed from the actual value.
• G-Counter display
Adds the point of the acceleration level. The point
is determined after a lapse of 1 hr drive or at power
off (ex; ACC Off), and then it will be displayed by the
graph. Furthermore, it displays the average of the past
data by the line. (The scale of graph is determined
along with the largest point among the past 10 data.)
• The value of G-Meter display and G-Counter display
can be reset by <G-Analyzer Reset> (page 44).
7 Exit display control mode
Press the [6] ("RTN") button.
TEL Mute
The audio system automatically mutes when a
call comes in.
When a call comes in
"CALL" is displayed.
The audio system pauses.
Listening to the audio during a call
Press the [SRC] button.
The "CALL" display disappears and the audio
system comes back ON.
When the call ends
Hang up the phone.
The "CALL" display disappears and the audio
system comes back ON.