TK-7180
10

5.

Voice Guide & Storage Unit (VGS-1 : Option)

5-1. Installing the VGS-1 unit in the transceiver

1. Remove the cabinet, top packing and shielding plate of the
transceiver.
2. Attach two cushions to VGS-1 as shown in Figure 5. ( q)
Note : Be sure not to cover the connector with the bottom
cushion.
3. Insert the VGS-1 connector (CN1) into the TX-RX unit (B/3)
connector (CN403). ( w)
Note : You must setup using the KPG-89D.
CN1
CN403

q

w

Cushion
(G13-1994-04)
20 x 30 x 12 mm
Cushion
(G13-1992-04)
21 x 21 x 2.5 mm
VGS-1

Connect the KRK-10 main panel to the rear panel

with the cable

8. Insert one 14-pin connector of the cable (E30-7514-05)
into the connector (CN3) of the interface unit (A/2) of the
main panel. ( !1 )
9. Secure the cable bush on the main panel and fit the water-
proof packing (orange) ( !2 ) securely over top.
CN4
CN3

!8 !8

!7

!6

!5

!2

!2

!3

!4

!4

!1

(Right side)
10. Install the molded cover ( !3 ) over the connector on the
main panel and secure it with two screws ( !4 ).
11. Insert the other 14-pin connector of the cable into the
connector (CN4) of the interface unit (B/2) of the rear
panel. ( !5 )
12. Secure the cable bush on the rear panel and fit the water-
proof packing (orange) ( !6 ) securely over top.
13. Install the molded cover ( !7 ) over the connector on the
rear panel and secure it with two screws ( !8 ).
Note : A cable can be connected from the left side as shown
in the Figure 4-5 or from right side.
However, the 14-pin connector must be connected to correct
direction.

Fig. 4-5

Fig. 5

INSTALLATION