TK-7180
45
Item Condition
Measurement Adjustment
Specifications/Remarks
Test-
equipment Unit Terminal PartsUnit Method
ADJUSTMENT
6. High RSSI 1) Adj item : [n HRSSI] SSG Rear ANT After input signal The following erroneous
adjust Adjust : [✳✳✳] panel from SSG, press [B] performance may occur if any
• Narrow SSG output : –70dBm AF VTVM EXT. SP key. That numeric irregular RSSI adjustment,
(MOD : 1kHz/±1.5kHz)
Oscilloscope
will be stored in such as pressing the [B] key
memory. assigned for determination
2) Adj item : [nL HRSSI] when it is the ANT OPEN
[nC HRSSI][nH HRSSI] state, is performed.
Adjust : [✳✳✳] • The antenna bar ( ) cannot
appear correctly.
• Wide 4k 3) Adj item : [s HRSSI] • Scan does not stop.
Adjust : [✳✳✳]
SSG output : –70dBm
(MOD : 1kHz/±2.4kHz)
4) Adj item : [sL HRSSI]
[sC HRSSI][sH HRSSI]
Adjust : [✳✳✳]
• Wide 5k 5) Adj item : [w HRSSI]
Adjust : [✳✳✳]
SSG output : –70dBm
(MOD : 1kHz/±3.0kHz)
6) Adj item : [wL HRSSI]
[wC HRSSI][wH HRSSI]
Adjust : [✳✳✳]
TC301
TC302
ANT
CV
CV
RXD
TXD
RST2
PSW
PSENS
TX-RX UNIT (B/3)
Foil side view
TX-RX UNIT (B/3)
Component side view

Adjustment Points