KDC-MP925/W8027

27
ANAMALAKAJ
1
2
3
4
5
6
7
1.35V
3.3V
0V
0V
5.0V
0V
5V
0V
3.3V
0V
3.3V
0V
0V
3.3V
5.0V
2.4V
5.0V2.4V
IC10
IC1
SWITCH UNIT (X16-2080-XX)
: GREEN
KDC-MP925/W8027 (2/3)
IC9
: BLUE
LED SW
Q10
D13
BR24C01AFV-WIC1
J1
EEP ROM
:
(X16-2080-xx)
Q9
IC2 : MX23L3213TG114
IC3 : MBM29LV004T-90
IC4 : S-816A34AMCT2G
IC6 : TC74HC4050AFT
IC7 : TC7WT126FU
IC8 : RS-171
IC9 : TC7WH32FU-F
IC1 : 703132GJ011-A
Q1 : 2SB1188(Q,R)
Q3 : 2SC2713
Q5,6,8 : 2SA1774
:DTC114EEQ7 :2SC4667Q9 :2SC4617
UMX2N
D1-5 : DA204U
1
(X16-2530-xx)
(GREEN)
GND LINE
B LINE
D14
Q11
LED SW
(RED)
SPECTRUM
ANALAYZER
BA3830FIC10 :
2SB1132:Q2
2SA1163:Q4
Q10,200
Q11 :
B30-1575-05D13 : B30-2233-05D14 :
FL
CONTROL
GRADATION
FL BK SW
S-816A25AMCT2GIC5 :
10K
R43
10K
R42
240
F2-20
F2-19
F2-18
VDD2
VSS2
VSS1
VDD1
S03
S02
S01
CLK
S11
S12
S13
F1-3
F1-2
F1
-
1
3
2
6
5
4
9
8
7
C25
2.2
C26
0.1
15
BK
14
13
10
18
17
16
20
19
16
78
77
76
75
74
47K
CP31
47K
CP32
F06
RELV
VCC
10
12
11
F03
F04
F05
14
13
15
111
79
33K
R40
RST
F01
F02
18
17
R39
C30
3
REIN 6
7
8
9
RSTC
BISC
GND
10
4
5
RENF
LNIN
R36
10K
R35
1
2
R02
R01
LNNF R37
R38
270K
270K
10
TP1
TP2
TP3
TP4
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
N.C
PAN-DET
N.C
N.C
SDA
N.C
N.C
SCL
N.C
N.C
VDD
N.C
N.C
GND
N.C
CP1
100
A1
4
3
GND
A2
1
2
A0
WP
SDA
SCL
VCC
5
6
7
8
MODEL NAME No.
UNIT
KDC-X969
KDC-9023R
KDC-PSW9524
FX-9000
0-10
0-01
YES
NO
CP1 IC1
YES
NO
G22
G
27 G28 G3G30G29 G31 GB G1 G2 G6G4 G5 G7 G8 G9 G11G10 G12 G14G13 G15 G19G17G16 G18 G20 G21 G25G23 G24 G27G26 G28 G30G29 G31 GC
R28
2.2K
2.2K
R29
R30
2.2K
F1
52
49
55
87
F2
22
108
NO
YES
AMODEL NAME
0-11
0-10
UNIT
No.
NO
YES
Q10
D13
NO
YES
R41
180
R45
4.7
C32
C33
4.7
C34
4.7
100K
R48
330
R47
4.7K
R46
R44
100K
A1
Y2
GND
4A2
B1
2
3B2
VCC
Y1
18
5
7
6
0.1
C27
100
R49
85
43
18
22K
50
LAT
11
12 GCP
0
10uH
0
7
+
8
9
C29
3300P
2.2
C31
73
R34
C28
22K
3300P
15K
4
R41-43
NO
YES
CP30
KDC-X879
FX-9100
KDC-X979
KDC-PSW9527
KDC-W9027
KDC-9026R

192x36 Dot Matrix

CAUTION : For continued safety,

replace safety critical components

only with manufacturer’s recom-

mended parts (refer to parts list).

Indicates safety critical compo-

nents. To reduce the risk of elec-

tric shock, leakage-current or re-

sistance measurements shall be

carried out (exposed parts are ac-

ceptably insulated from the supply

circuit) before the appliance is re-

turned to the customer.

DC voltages are as measured

with a high impedance voltme-

ter. Values may vary slightly

due to variations between indi-

vidual instruments or/and units.

X16-2530-11 (3/3), X16-2080-10 (1/1)

DTA123JK

DTC114EE

DTC114YUA

DTC143TUA

UN5114

UN5213

UN5214

UN5216

2SA1163

2SA1576A

2SC2713

2SC4617

2SD2114K

2SB1132

2SB1188

2SB1443

2SA1774

2SC4081

UMX2N

DTA124EUA

DTC124EUA

DTC144EUA

NJM4565M-TE2