3. Installation Locations
Locations To Avoid
IMPORTANT: Improper location can affect the sensitive electronic com- ponents in this alarm. To avoid causing damage to the unit, to provide optimum performance, and to prevent unnecessary nuisance alarms:
•Do not install in kitchens, garages or furnace rooms that may expose the sensor to substances that could damage or contaminate it.
•Do not install in areas where the temperature is colder than 0°C or hotter than 40°C such as crawl spaces, attics, porches and garages.
•Do not install within 1.5m. of heating or cooking appliances. (Kidde recommends 3m. to prevent nuisance alarms).
•Do not install near vents, flues, chimneys or any forced/unforced air ventilation openings.
•Do not install near ceiling fans, doors, windows or areas directly exposed to the weather.
•Do not install in dead air spaces, such as peaks of vaulted ceilings or gabled roofs, where CO may not reach the sensor in time to provide early warning.
•Do not install this unit near
•Do not obstruct the vents located on the alarm. Do not place the alarm where drapes, furniture or other objects block the flow of air to the vents.