Kidde KN-COB-BCA Features and Operation of Digital Display Model, Normal Operation, see figure

Models: KN-COPP-BCA KN-COB-BCA

1 15
Download 15 pages 59.8 Kb
Page 6
Image 6
Features and Operation of Digital Display Model

Features and Operation of Digital Display Model

Your new Kidde Battery Powered CO Alarm utilizes sophisticated electronic components to protect you and your family from the dangers of CO.

Unique features include a digital display capable of displaying CO concentrations in (PPM) Parts Per Million and the highest levels of CO detected. Familiarize yourself with these features:

Digital Display Backlight Feature

To help see the displayed reading in the dark, a backlight appears when the peak level button is pressed.

Digital Display - Shows CO level in PPM

Your Kidde CO alarm continuously displays a digital readout of the CO level in Parts Per Million (PPM). The digital display is capable of detecting and displaying readings between 30 and 999 ( P P M ) . A reading of 0 PPM is expected under

normal conditions

(see figure 2).

Figure 2

You will become accustomed to glancing at the

display in much the same manner as you look at a thermometer or clock. The unit will not automatically display reading below 30 PPM. However, readings between 11 and 999 PPM will be stored in the Peak Level Memory.

Features and Operation of Digital Display Model (continued)

Other Possible Displays and Their Meanings

The following symbols will appear on the display during normal or error operations, and are explained below.

Normal Operation

Normal operation (see figure 3) with a full battery.

 

The dot in the lower right corner cycles on and off

 

every 5 seconds. If CO is present the display will

 

indicate the reading in Parts Per Million (PPM).

Figure 3

Normal Operation following Power-up or Reset

Figure 4 shows the normal display immediately after installing batteries or after the test/reset button is pressed. The display should change to the normal display (see figure 3) approximately

30 seconds after pressing the test/reset button. Figure 4 (see Test/Reset Button page 13).

If the test/reset button is pressed, the alarm will sound. The display will show a number during the time that the alarm is sounding. This number is a normal part of the test function, and does not indicate a CO reading.

Peak Level Display

When the peak level button is pressed and held, the display shows the highest CO reading taken by the CO alarm since its last peak level reset or power-up(Example shown in Figure 5). The backlight will illuminate for several seconds after

the peak level button is pressed to help see the Figure 5 reading.

Although the peak level feature will display levels below 30 PPM, these levels will not result in an alarm no matter how long the device is exposed to these levels.

10

11

Page 6
Image 6
Kidde KN-COB-BCA Features and Operation of Digital Display Model, Digital Display Backlight Feature, Normal Operation